troubleshooting   

and maintenance

troUbleShootinG

apparent Problem

check Point

Solution

Cut-off rod fails to heat properly

The cut-off rod and circuit board must be 
tested together. Use procedure described 
herein. Check Fuse.

Replace if necessary

Cut-off rod temperature is too 
high or too low

Rheostat knob on the printed circuit board 
(see circuit board on page 6, Rheostat = 
R5 knob) can be adjusted by an electrical 
technician. Note: rheostat is fragile. Turn 
clockwise to increase heat and to decrease 
resistance of R5. Turn counterclockwise  
to decrease heat and increase resistance  
of R5.

Replace if necessary

Hot plate fails to heat or  
overheats

Visually inspect the wire and connections 
under the hot plate for burning and replace 
if burnt. Visually inspect the lead on the 
heating element for burning and replace if 
burnt.

If burning or short circuiting does 
not show, replace the thermostat.  
If burnt replace element.

maintenance

Cleaning and Service:

• 

 Unplug unit before any maintenance or cleaning.

• 

 When dirt is stuck on the nested cut-off rod and hot plate, clean with a cotton cloth. Don’t use metal or sharp  
objects. Don’t immerse equipment in water or spray water directly on the unit. Do not perform any actions which 
could be dangerous for the operator or those around the machine.

• 

 When working: if light is not working or heated cut-off rod and hot plate is not heating, turn off power, check the 
power cord. If it is still not working, contact a qualified technician.

• 

 The equipment must be serviced by trained technicians.

• 

 If fuse is not the correct setting, change to a 1 Amp fuse.

WarninG:

• 

For protection against fire or electric shock, replace with type 6D and 1 Amp fuse.

caUtion:

• 

This product has more than one power-supply connection point. Disconnect all power before servicing.

Содержание 53232

Страница 1: ...0 543 7374 www hubert com Hubert 53232 U L Listed Directory General and Safety Information 2 Technical Specifications 3 Operation 4 Film Roll Axle Assembly 4 Loading the Film Core Axle 5 Electrical Sc...

Страница 2: ...king area 5 Unplug the machine from the outlet when not in use Unplug the machine before assembly or disassembly and before cleaning or maintenance 6 Do not touch moving parts 7 Don t operate the appl...

Страница 3: ...late 10 Strip 11 Heat element 12 Clip 13 Heated cut off rod 14 Thermostats 15 Light 16 Fuse 17 Fuseholder 18 Cut adapt kit 1 19 Terminal blocks 20 Power cord 21 Main switch 22 PCB 23 Circuit 24 Cut ad...

Страница 4: ...plication information regarding film thickness and color Heated Cut off Rod The heated cut off Rod cuts the desired length of film The temperature is factory preset at 266 F 50 F and monitored and con...

Страница 5: ...he Film Roll against the taper of the Pin End Cap Make certain that the film will dispense from the bottom of the roll 4 Replace Wing End Cap and Screw tightly 5 Replace Axle and Film onto the Lower B...

Страница 6: ...lack sensor wires from terminals 5 and 6 If the reading across black sensor wires is over 1M Ohms or if there is no reading replace Cut Off Rod Testing the Circuit Board 1 Disconnect rod wires from Ci...

Страница 7: ...Visually inspect the lead on the heating element for burning and replace if burnt If burning or short circuiting does not show replace the thermostat If burnt replace element Maintenance Cleaning and...

Страница 8: ...Holder 11 32011 Film Core Axel 3 86857 Circuit Control Board 12 83842 Core Adaptor Set 4 81581 23 Heated Cut off Rod 13 16761 Bearing Block Set 5 17109 Heat Element 14 92004 Vinyl Film Retainer 6 229...

Отзывы: