background image

 

 

INSTALLATION 
MANUAL 

 

HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of tools and 

accessories other than the ones recommended herein. Any installation performed by unqualified personnel  voids the product warranty provided by 

HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these products. For advice concerning the 

general handling of these products please contact HUBER+SUHNER. 

HUBER+SUHNER AG 

Fiber Optics 

M

ASTER

L

INE 

U

ltimate 

Power

 

DOC-0000807936 Rev B 
 
June 23, 2020 
Page 1 of 11 

 

MASTERLINE Ultimate Power 

Table of contents 

• SAFETY NOTES .......................................................................................................................................................................................... 1

 

• HANDLING OF THE CABLING SYSTEM .................................................................................................................................................... 1

 

• HANDLING OF FIBER OPTIC ASSEMBLIES ............................................................................................................................................. 1

 

• RRH END OF ASSEMBLY .......................................................................................................................................................................... 2

 

• BASE STATION END OF ASSEMBLY ........................................................................................................................................................ 8

 

• POWER CODING ...................................................................................................................................................................................... 10

 

• REVISION HISTORY ................................................................................................................................................................................. 11

 

 SAFETY NOTES  

Installation and maintenance work on this device must be carried out only by an authorised 
electrician.  
National laws and regulations must be observed during installation. The housing and the 
components used must be checked for exterior damage prior to installation. If the cabling 
system is defective, it must not be used.  

 

 

HANDLING OF THE CABLING SYSTEM  

To avoid any damage due to improper installation, please note the following points: 

 

AVOID any additional stress on the connector head causing by twisting or bending dur-
ing routing or location 

 

AVOID installation paths around any sharp objects 

 

AVOID uncontrolled impacts of the connector head against any hard object 

 

AVOID any contact between the connector head and any additional substance such as 
glue, oil or fat, unless prior authorisation is given by HUBER+SUHNER AG 

See also the 

“User handling manual for cables and cable systems” available at 

www.hubersuhner.com/en/support 

 
 

HANDLING OF FIBER OPTIC ASSEMBLIES  

To guarantee proper performance, fiber optic assemblies must be handled carefully with due 
attention to the minimum bend radius and never exposed to dirt. 
See also the 

“User handling manual for cables and cable systems” available at 

www.hubersuhner.com/en/support 

 

Содержание MASTERLINE Ultimate

Страница 1: ...lectrician National laws and regulations must be observed during installation The housing and the components used must be checked for exterior damage prior to installation If the cabling system is def...

Страница 2: ...roducts For advice concerning the general handling of these products please contact HUBER SUHNER RRH END OF ASSEMBLY Step 1 Use a smartphone to scan the QR code on the side of the reel The QR code pro...

Страница 3: ...y be fore attaching the MLUP connector head to the mounting bracket Step 4 Use a rope to pull up the cable system Check the maximum pulling force at 50 C ambient temperature for 1 hour as specified on...

Страница 4: ...r all cable clamps are mounted Step 6 Secure the MLUP connector head on the mounting bracket by tightening the two M6 screws on the bottom left and top right corner Tighten the M6 screws using a torqu...

Страница 5: ...to an earth bar with a grounding assembly with minimum 16 mm2 6 AWG cross section Consider the correct order first the grounding wire lug secondly the washer thirdly the spring washer Tighten the M8 e...

Страница 6: ...plugging Mating Remove protection caps of the plug Twist 120 the coupling ring of the plug connector to remove protecting cap as shown Note the lock unlock symbol on the coupling ring Remove protecti...

Страница 7: ...concerning the general handling of these products please contact HUBER SUHNER Step 12 Ensure smooth routing of all cables from connector head to RRH equipment using HUBER SUHNER cable clamps which are...

Страница 8: ...BASE STATION END OF ASSEMBLY Step 1 Unwind the whole assembly from the reel and lay the cable to the end equipment Use the pulling eye to feed the power cable through a conduit Step 2 Remove gland nut...