Step 6: 

 

Use jumper cables to connect the MLUM sys-
tem to the RRH. The connectors can be en-
gaged in the available ports by applying gentle 
pressure. Turn the connector in the opposite 
direction to check that it is properly engaged. 
Please refer to the general instructions in the 
user manual for guidance on handling cables 
and laying multi-connector cables. 

 

 

Step 7: 

 

All jumper cables must be secured according 
to national and local regulations. The weight of 
the cable must be supported by the cable fas-
teners. 

 

 

Step 8: 

 

Once all the jumper cables have been con-
nected, the main feed can be connected to the 
base station or another signal source.  
The protective tube must be removed before 
connecting. 
When untwisting the protective tube, ensure 
that the cable is not twisted around its own 
axis.  

 

 

Step 9: 

 

Connect the MLUM housing to the base sta-
tion using suitable cables. 
The connectors can be engaged in the ports 
provided by applying gentle pressure. Turn the 
connector in the opposite direction to check 
that it is properly engaged. 
Please refer to the general instructions in the 
user manual for guidance on handling cables 
and laying multi-connector cables. 

 

 

 

REVISION HISTORY 

 

Revision 

Description of detailed changes 

Manager/Engineer 

Applicable 

date 

Rev. A 

First Version 

David Neher 

2020-07-06 

 
 
 

Содержание MASTERLINE Ultimate Micro

Страница 1: ...s HUBER SUHNER declines all liability and claims if the specifications are not met NOTES IN THIS MANUAL The following symbols are used in this manual Info notes Info notes contain important instructions for installation and proper use of the product throughout its life cycle The info notes also indicate that non compliance may result in material damage or financial loss Notes about hazards and saf...

Страница 2: ...Micro MLUM may only be lifted up as marked in red Make sure that the pull rope does not slip out of the bracket during pulling and that the pull rope has enough pulling force to safely lift the MLUM system Avoid buckling the cable or bending it at less than the minimum radius while the device is being raised All plug type cables must be unplugged prior to raising Step 2 Fixing Mast and wall mounti...

Страница 3: ... please contact HUBER SUHNER Step 3 The fiber optic cable must be secured accord ing to national and local regulations The weight of the cable must be supported by the cable fasteners Step 4 In the case of a daisy chain installation all the MLUM systems must be fastened in accord ance with steps 1 and 2 Step 5 Once all the MLUM systems have been fas tened in accordance with the national and re gio...

Страница 4: ...in the user manual for guidance on handling cables and laying multi connector cables Step 7 All jumper cables must be secured according to national and local regulations The weight of the cable must be supported by the cable fas teners Step 8 Once all the jumper cables have been con nected the main feed can be connected to the base station or another signal source The protective tube must be remov...

Отзывы: