Installation Instruction for new 
construction of a Door Jamb Switch 
Kit (RDS50Z) 

Normally Closed  

 

Door open lights ON, Door closed 
lights are OFF. 
3A, 125 Vac.   4.6 Cu Inch.  

 

NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes and the 
following instructions. 
CAUTION: 
RISK OF ELECTRICAL SHOCK. Disconnect power before installing. 
CAUTION:  Make sure that you follow local Electrical rules and regulations. If unsure, consult a qualified electrician. 
NOTE
: Do not install on a Metal door frame 
NOTE: Use Copper Conductors only. 

 

1)

 

Create suitable cable entry in Door Frame. 

2)

 

Make an opening in Door Jam to suit Junction Box. (See 
Fig. 2 for dimensions of Box).  Create recess for Box 
Ears to ensure Switch Plate is flush to door jamb when 
installed. 

3)

 

Remove a knock out in Junction Box to accommodate 
cable entry. 

4)

 

Insert cable through knock out and secure to box with 
approved connector (not provided). 

5)

 

Fasten box to door jamb with 4 wood screws 
(provided).  

6)

 

 Connect GREEN/ BARE (ground) wire to ground screw 
in back of junction box, connect Line and Load wires to 
switch pig tail wires following national and local 
electrical codes Use Fig. 1 for guidance.   

7)

 

Adjust shaft to proper depth on switch plate using 
locknuts (provided) at the back and front of the switch 
assy’ for contact with round kicker plate .  

8)

 

Using 2 short screws (provided), fasten the switch 
plate to the box.  

 

9)

 

With power ON, Open and close door to verify proper 
operation of the switch and adjust switch depth 
accordingly.  

 

 

10)

 

Once proper positioning is established, install the 
round kicker plate on the door side to face the switch 
button, by fastening with the wood screw (provided). 

 

 
11) Installation is complete. 

 

 

 