![Hubbell Gai-Tronics REDA LERT 234 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/hubbell/gai-tronics-reda-lert-234/gai-tronics-reda-lert-234_manual_2180430011.webp)
Pub. 42004-510C
234/234SBA RED ALERT
®
Tower Assemblies
Page 10 of 14
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-510C.docx
11/19
Model 84503-30x Tower Panel Light
1.
Align the panel light assembly inside the tower
(see Figure 9).
2.
Model 84503-301 (120 V ac):
Extend the black
(hot), the white (neutral), and the green (ground)
wires to the base of the tower (these wires, along
with the strobe wires, will be connected later to
the incoming power conductors in accordance
with applicable electrical codes).
Model 84503-302 (10–33 V dc):
Extend the black
(−) and the white (+) wires to the base of the
tower (these wires, along with the strobe wires,
will be connected later to the incoming power
conductors in accordance with applicable
electrical codes).
3.
Apply a small amount of clear RTV silicone
sealant or equivalent to the mounting screw
threads to reduce the possibility of rust forming in
the threads.
4.
Secure the light assembly with the two mounting
screws provided.
Figure 9 Panel Light Assembly