Pub. 42004-541A
Hands-free VoIP Telephone Manual
Page 10 of 24
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-541A.docx
02/20
Models 393-710, 393AL-710, and 394AL-712 (Surface Mount
Applications)
1.
Remove the four security screws from the
front panel.
2.
Position the enclosure on the mounting
surface.
The enclosure has four 0.28-inch diameter
mounting holes in a 7.0
×
8.5-inch hole
pattern.
3.
Secure the enclosure to its mounting surface
with four ¼-inch diameter bolts of the
appropriate length for the surface.
N
OTE
:
When using the GAI-Tronics Model 231-
001 Pole Mounting Kit:
follow the
mounting instructions provided in the
kit.
N
OTE
:
Installation of a (customer-supplied)
surge suppresser is recommended on the
Ethernet cable for outdoor installations.
4.
For Model 393-710 only:
Create a conduit access hole using a hole punch equivalent in size to the
conduit diameter.
•
Bottom entry is strongly recommended.
•
Insert a conduit fitting in the access hole.
5.
Install conduit as required (see the Conduit Installation Details (Surface-Mount Models) section on
Page 9).
6.
Use silicone sealant or equivalent around and inside all conduit entries.
7.
Pull the Ethernet cable through the conduit and terminate the cable (see the Field Wiring section on
Page 18).
8.
Connect any desired peripheral devices (see the I/O section on Page 19)
9.
Perform the initial programming of the telephone (see the Programming section on Page 21).
10.
Verify telephone operation by calling to and from another telephone.
11.
Verify operation of peripheral equipment.
12.
Attach the front panel assembly to the rear enclosure using the four security screws.
13.
Torque the screws to 10–12 in·lb.
Figure 5. Model 393-710 VoIP Telephone
in a Non-metallic Enclosure