Conduit Installation Details (Surface-Mount Models)
GAI-Tronics recommends installing Ethernet and power lines in conduit to protect against accidental
damage and vandalism. To prevent moisture from entering the enclosure, the following is recommended:
•
Conduit should enter the enclosure from the bottom.
•
Sealed fittings should be installed at all cable entry points.
•
Silicone sealant or equivalent should be applied around and inside all conduit entries.
Please refer to the examples below for the recommended conduit installation details.
Figure 1. Bottom entry conduit recommended for
non-metallic enclosures
Figure 2. Top entry conduit installation for non-
metallic enclosures (NOT recommended)
Figure 3. Bottom entry conduit installation details
for metallic enclosures
Figure 4. Top entry conduit installation details for
metallic enclosures (NOT recommended)