background image

Pub. 42004-501C 

Division 2 VoIP Telephones

—Wired and WiFi 

Page 16 of 22

 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-501C.docx 

03/20 

12.

 

Click the 

R

ESTART

 button, located in the 

R

ESTART 

M

ODULE

 section. 

 

The web page will show 

R

EBOOTING

 while the WiFi module is restarting. 

 

Both LEDs on the RJ-45 jack 

J2

 will turn OFF for several seconds while the WiFi interface 

restarts. 

 

The green LED turns ON first; after the WiFi interface restarts. 

 

The yellow LED turns ON when the WiFi interface connects to the newly configured network. 

13.

 

Continue with the configuration of the VoIP telephone PCBA (see the VoIP Telephone Setup 
section). 

14.

 

If an incorrect WEP Key or Pass Phrase is entered:

  Follow the instructions in the next section (see 

the Reset WiFi Interface section). 

N

OTE

:

  The WiFi module is no longer an access point on its own network (HF-A11_AP).  The WiFi 

module should now be connected to or trying to connect to the newly configured wireless 
network.  The browser web page will not change from showing 

R

EBOOTING

 because the PC is 

no longer connected to the HF-A11_AP network. 

Reset WiFi Interface

 

Use this procedure to erase the current WiFi configuration in the telephone and configure the WiFi 
adapter with the factory default settings. 

1.

 

Press the 

RL

OAD 

button for 10 seconds to reset the WiFi interface back to factory default settings. 

 

The 

RL

OAD

 button is on the WiFi interface PCBA. 

 

Both LEDs on the RJ-45 jack (

J2

) turn OFF for several seconds while the WiFi interface resets. 

 

Wait for the green LED to turn ON before trying to connect to the HF-A11_AP network. 

2.

 

Follow the instructions in the First Time WiFi Interface Setup section to connect to the HF-A11x_AP 
network and change the configuration settings. 

N

OTE

:

  The telephone’s power must be cycled before it will connect to the wireless network after 

changing the WiFi interface configuration if the VoIP telephone was configured for DHCP. 

VoIP Telephone Setup

 

1.

 

Connect a PC to the same network as the VoIP Class I, Division 2. 

2.

 

Log into the unit’s web interface. 

The unit is factory configured with a static IP address: 

192.168.1.2.

 

3.

 

Enter the username and password when prompted. 

The initial factory settings are: 

  U

SER 

N

AME

:

  

user

 

  P

ASSWORD

:

  

password

 

4.

 

Change the username and password upon first login. 

This security measure helps prevent unauthorized changes to the VoIP telephone’s interface 
configuration. 

Содержание GAI-TRONICS Division 2 351-7 7 Series

Страница 1: ...6 VoIP 6 VoIP WiFi 6 VoIP Subscriber Tips 7 Operation 7 Handset Receiver Volume Control 7 Model 351 7x7 351 7x8 351 8x7 and 351 8x8 Handset Operation 7 Model 351 7x9 351 7xA 351 8x9 351 8xA Headset Op...

Страница 2: ...ontrol 17 Input Contacts 17 Output Contacts 18 Maintenance 18 Status Indication 18 Power 18 Heartbeat 18 Link 18 Speed 18 WiFi Activity WiFi Units Only 18 WiFi Ready WiFi Units Only 18 WiFi Connected...

Страница 3: ...er operation is identical to that of a standard analog telephone simply lift the handset and dial the desired telephone number Autodial telephone models dial a preprogrammed number when the handset is...

Страница 4: ...Phone with Relay 351 817 Div 2 VoIP WiFi AC Phone 351 827 Div 2 VoIP WiFi DC Phone 351 818 Div 2 VoIP WiFi AC Phone with Relay 351 828 Div 2 VoIP WiFi DC Phone with Relay Handset with Auxiliary Jack...

Страница 5: ...et Options Wired 7 WiFi 8 AC 1 DC 2 POE 3 Phone 7 Phone with Relay 8 Phone with Auxiliary Jack 9 Phone with Auxiliary Jack and Relay A Orange 1 Gray 2 Yellow 3 Red 4 None 0 6 foot 1 15 foot 2 6 foot H...

Страница 6: ...A Class 0 configurable via web page download or Telnet four configurable auxiliary inputs two configurable dry contact outputs relay units only Hardware Description External Division 2 VoIP telephones...

Страница 7: ...et headset adapter PCBA and keypad PCBA are mounted to the front cover Amplifier only versions do not include a keypad PCBA see Figure 3 Model 351 8xx VoIP Telephones The power supply input power term...

Страница 8: ...Ethernet network with SIP Session Initiation Protocol server Call capacity is limited by the customer s LAN media capabilities and the services available at each end point VoIPWiFi Two telephones can...

Страница 9: ...l to adjust the handset receiver volume The volume decreases from 20 dB to 12 dB to 0 dB and back up to 20 dB of the original signal with each button press The signal level is reset to 20 dB after the...

Страница 10: ...lowing precautionary steps to protect the unit during installation Install this unit using appropriate Division 2 wiring methods Run the subscriber line inside conduit to ensure that the unit is vanda...

Страница 11: ...tation enclosures is 48 inches 1219 mm to the center of the bottom mounting holes of the enclosure telephone are not supplied with conduit or cable openings 2 Remove the front panel 3 Drill or punch e...

Страница 12: ...ws from the power supply cover located in the rear enclosure and remove the power supply cover 2 Connect the incoming power conductors to the 3 point terminal block in the rear enclosure see the Local...

Страница 13: ...ductor No 18 AWG is typical Inputs two conductor No 22 AWG is typical Output contacts two conductor No 18 AWG is typical Figure 7 Internal PCBA Connections NetworkCable Connect a Cat5 or better UTP ca...

Страница 14: ...t INPUT 1 4 and common COM on terminal block P12 see Table 4 The inputs are configurable Refer to GAI Tronics Pub 42004 548 for configuration instructions see the Reference Documentation section Table...

Страница 15: ...otocol between the desired locations before attempting to configure the GAI Tronics VoIP Telephones First Time WiFi Interface Setup wireless telephones only Setup the WiFi interface to configure the t...

Страница 16: ...tton the web page will show Set Successfully Restart to use new setting 6 Restart to use the new setting and then click on the STA INTERFACE SETTING selection The STA INTERFACE SETTING web page opens...

Страница 17: ...k and click the APPLY button The AP s SSID security mode and encryption type fields will be filled in when the STA interface setting webpage opens again NOTE Manually enter the AP s SSID security mode...

Страница 18: ...t WiFi Interface Use this procedure to erase the current WiFi configuration in the telephone and configure the WiFi adapter with the factory default settings 1 Press the RLOAD button for 10 seconds to...

Страница 19: ...rowser such as Internet Explorer to view and change settings within a single unit Configuration files are ASCII text files containing configuration options that can be read and edited by a knowledgeab...

Страница 20: ...ne Heartbeat The HB LED located on the VoIP PCBA see Figure 13 flashes when communication over the LAN is established Link The LNK LED located on the VoIP PCBA see Figure 13 indicates an active networ...

Страница 21: ...return authorization number will be issued if service is required Equipment must be shipped prepaid to GAI Tronics with an RA and a purchase order number Repairs or a replacement will be made in acco...

Страница 22: ...e calls Check the connection of the LAN cable Verify that power is applied to the unit Verify the LAN parameters have been configured properly Verify the telephone has been set up on the network no po...

Страница 23: ...ing WiFi Network Standards IEEE 802 11b g n Frequency 2 412 GHz to 2 484 GHz Configuration embedded web server configuration file download password protection Handset Audio Analog microphone gain 30 d...

Страница 24: ...kg Approvals With antenna NRTL listed for USA and Canada Class I Groups A B C and D Division 2 Class II Groups F G Division 2 Class III Division 2 Hazardous Locations Temperature code T4 Outdoor envir...

Отзывы: