18
VoIP Telephone.
warning label, which can be fixed to the front of the telephone, is
provided.
5.4. Titan Installation
1. To prepare for installation, open the door (where fitted), then undo the
four retaining screws to remove the faceplate from the rear enclosure. A
3mm Allen key is required.
Caution
– take care to support the spring-loaded door whilst open
to prevent it slamming shut and trapping fingers.
2. The Titan telephone is intended for vertical installation to a wall or pole.
Select the required mounting method (section 4.2) and mount the rear
enclosure first where applicable.
3. Route the required cables through glands as appropriate, and make
connections following section 5.5. When fitting mains wiring to this
product that is not wholly run within trunking, it is important that the
strain relief is correctly installed and tested to ensure there will be no
disturbance to the wire terminations. As a minimum the cable must
withstand a pull of 100N (approx 10kg force or 22.5lbf) without visible
movement. If conduit is used, mains cables must be secured elsewhere.
4. Re-fit the faceplate ensuring a weatherproof seal
5. Test the operation of the telephone. Installation is now complete.
5.5. Titan Connections
Make the appropriate connections as shown on the diagrams below.
Take particular note of the cable clamping arrangements
– all cables must be
securely clamped in the clamps provided.
0V
+
0V
OP1
OP2
-
IP1
IP2
IP3
IP4
AUX
1A
-T
Barrier
Clamp (on
secondary
insulation)
Connector Legend
Connection
to Output 1
Connection
to Input 1
Cabling example showing connections to Input 1, Output 1 and aux. DC supply
AUX 24-48Vdc
Connection