Auteldac 6
13
5.4.1
Connection to the network
The terminal cover identifies the function of each of the terminals.
The middle eight terminals are for the Ethernet connection identified
by wire colour:
W/BL
White / Blue
BL
Blue
W/BR
White / Brown
BR
Brown
W/GR
White / Green
GR
Green
W/OR
White / Orange
OR
Orange
Note:
the Ethernet cable termination is to TIA/EIA-568 T568B
5.4.2
Power
Power can be provided by either
•
PoE (Vmax=57Vdc) using option B - spare pairs
only
.
Auteldac 6 cannot use PoE on data pairs.
•
DC power input (AUX POWER) Vmax=53V , Imax=250mA.
If both power supplies are connected the telephone will give
preference to Aux power. If Aux power is disconnected the
telephone will reboot to renegotiate PoE. If PoE power is lost while
Aux power is connected the telephone will not reboot.
5.4.3
Earth connection
IMPORTANT:
Auteldac 6
must
be connected to an equipotential
bonding system for the whole area in which the intrinsically safe
equipment is being used.
Auteldac 6 is provided with an externally facing earth bonding screw
for this purpose.