background image

(Rev. 10/06)

Warranty

Equipment.

 GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any

GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall
comply with the then-current product specifications and product literature, and if applicable, shall be fit
for the purpose specified in the agreed upon quotation or proposal document.  If (a) Seller’s goods prove
to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose
specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above,
Buyer may return such goods to GAI-Tronics nearest depot repair facility, freight prepaid, at which time
they will be repaired or replaced, at Seller’s option, without charge to Buyer.  Repair or replacement shall
be Buyer’s sole and exclusive remedy.  The warranty period on any repaired or replacement equipment
shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original
equipment was shipped.  In no event shall GAI-Tronics warranty obligations with respect to equipment
exceed 100% of the total cost of the equipment supplied hereunder. Buyer may also be entitled to the
manufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder.  The applicability
of any such third-party warranty will be determined by GAI-Tronics.

Services.

  Any services GAI-Tronics provides hereunder, whether directly or through subcontractors,

shall be performed in accordance with the standard of care with which such services are normally
provided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will re-
perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided
any and all issues are identified prior to the demobilization of the Contractor's personnel from the work
site. Re-performance of services shall be Buyer's sole and exclusive remedy, and in no event shall GAI-
Tronics warranty obligations with respect to services exceed 100% of the total cost of the services
provided hereunder.

Warranty Periods.

  Every claim by Buyer alleging a defect in the goods and/or services provided

hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty
periods as set forth above.  Provided, however, that if the defect complained of is latent and not
discoverable within the above warranty periods, every claim arising on account of such latent defect shall
be deemed waived unless it is made in writing within a reasonable time after such latent defect is or
should have been discovered by Buyer.

Limitations / Exclusions.

  The warranties herein shall not apply to, and GAI-Tronics shall not be

responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent
caused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with the
equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the
equipment.  THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND
EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BY
OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Return Policy

If the equipment requires service, contact your Regional Service Center for a return authorization number
(RA#).  Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number.  If the equipment is under warranty, repairs or a replacement will be made in
accordance with the warranty policy set forth above.  Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.

Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the
Regional Service Center closest to you.

Содержание GAI-TRONICS 400-001

Страница 1: ...ing 3 Hardware Configuration 4 External 4 Internal 5 Wiring 5 Station Wiring 5 System Line Balance 6 System Wiring 7 Field Wiring Terminations 7 TB1 Speaker Terminal Block 7 TB2 AC Power Terminal Block 8 TB3 DC Power Terminal Block 8 TB4 Audio and Low Voltage Control Terminal Block 8 P1 Front Cover Wire Harness Connections 9 P3 Balanced Unbalanced Jumper 9 SW1 Master Slave Switch 9 Cover Installat...

Страница 2: ...2 1212 Fax 610 796 5954 VISIT WWW GAI TRONICS COM FOR PRODUCT LITERATURE AND MANUALS Speaker Model 400 001 Only 13 Station 13 Environmental 13 Approvals 13 Appendix A InterfacingaModel400 001RigComStationtoaMS39xxRigComStationSystem 14 Appendix B InterfacingaModel400 001RigComStationtoEZPageStations 16 ...

Страница 3: ... Class I Div 1 Groups C and D Model 400 002NS Class I Div 1 Groups B C and D The system provides push to talk release to listen operation and has a local on off volume control switch to activate and control the volume level for each station independently The Model 400 001 includes an attached speaker and driver unit The Model 400 002NS does not include the speaker and driver unit but does have a 1...

Страница 4: ...urer should not be used as they may cause hazards This permanently connected apparatus must have an ALL POLE MAINS switch with a contact separation of at least 3 mm in each pole incorporated in the electrical installation of the building WARNING To reduce the risk of fire or electrical shock do not expose this apparatus to rain or moisture Installation These enclosures must be installed by trained...

Страница 5: ... energized Speaker Horn Assembly Model 400 001 Only The Model 400 001 Speaker Horn Assembly must be assembled prior to installation 1 Unpack the unit 2 Locate the speaker horn and driver unit 3 Place the speaker bell over the driver bushing 4 Position two large diameter fiber washers with the large diameter steel washer sandwiched between them on the speaker bushing 5 Place the small diameter rubb...

Страница 6: ...UME PUSH TO CALL GAI TRONICS CORPORATION P O BOX 1060 READING PA 19607 SUITABLE FOR USE IN HAZARDOUS LOCATIONS CLASS I DIV I GROUPS C D WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES CONDUIT SEALS MUST BE INSTALLED WITHIN 18 INCHES OF ENCLOSURE AMBIENT TEMPERATURE 20 C TO 60 C No 400 001 RIGCOM MASTER SLAVE COMMON DATE CODE 17R9 ...

Страница 7: ...iring through the conduit or cable gland and into the right side hole as viewed from the front of the station 4 Attach the wires to the terminal blocks located on the PCBA within the enclosure see Figure 4 and the Field Wiring Terminations section for connection points and descriptions 5 If using the 10438 002 Auxiliary Microphone Assembly Connect the assembly to the station at terminal block TB4 ...

Страница 8: ...lation into a customer supplied junction box NOTE Only one line balance resistor assembly is needed per system Install the resistor assembly in a customer supplied junction box that is close to the center of the system when cable runs approximately 4000 feet 1219 m or longer are used see Figure 5 and Figure 6 NOTE The junction box must be suitable for the applicable hazardous location where it is ...

Страница 9: ... each station in talk mode the signal level reduces by half see Figure 7 for systems with more than ten stations to determine the maximum line distance Figure 7 Number of Stations vs Line Length Field Wiring Terminations TB1 Speaker TerminalBlock Table 1 Speaker Output Connection at Terminal Block TB1 Name Pin No Description 16 1 16 ohm terminal for external speaker connection 8 2 8 ohm terminal f...

Страница 10: ...minal No connection when external dc power supply is not used TB4 AudioandLow VoltageControl TerminalBlock Table 4 Audio Signal and Low Voltage Control Connections at Terminal Block TB4 Name Pin No Description AUX MIC 1 Positive terminal for the auxiliary microphone AUX MIC 2 Negative terminal for the auxiliary microphone EXT CONT 3 Talk listen control signal for Master Slave operation No connecti...

Страница 11: ...position for common line operation Cover Installation 1 Inspect and clean the machined flange flame joint surfaces of both the cover and box Surfaces must be smooth free of nicks scratches dirt or any foreign particle build up that may prevent a proper seal Surfaces must seat fully against each other to provide a proper explosion proof joint 2 Clean the surfaces by wiping them with a clean lint fr...

Страница 12: ...down while the operator talks Releasing the switch deactivates the microphone and returns the unit to listen mode Master Slave System A master station controls the talk listen function of the slave units through external control wiring in the master slave configuration Slave stations are in talk mode allowing the master station to monitor the slave s audio when the master s push to talk is not act...

Страница 13: ...ce program will increase the reliability of the GAI Tronics station The GAI Tronics Field Service Department can formulate a service contract suited to specific needs for preventive maintenance WARNING Before performing any of the following preventive maintenance steps remove all power from the station CAUTION To reduce the risk of ignition of hazardous atmospheres disconnect the equipment from th...

Страница 14: ...ly inspect the system cable for accidental crossing of cable pairs or grounds Replacement Parts and Accessories Contact GAI Tronics for replacement part information Table 5 Available Accessories for RigCom Stations Part No Description 12801 002 auxiliary microphone 51052 003 auxiliary footswitch 10438 002 microphone I S barrier kit contains 12801 002 auxiliary mic assembly 12807 001 connector kit ...

Страница 15: ...th slots Connections plug in style terminal blocks Conduit entries bottom two 3 4 inch NPT top one 1 2 inch NPT Model 400 002NS only Dimensions 20 00 H 10 31 W 14 21 D in 508 0 261 9 360 9 mm Shipping weight Model 400 001 36 0 lb 16 4 kg Model 400 002NS 23 0 lb 10 5 kg Environmental Temperature range operating and storage 4 ºF to 140 ºF 20 ºC to 60 ºC Approvals The models below are approved for th...

Страница 16: ... operate in an unbalanced or balanced system In a balanced system the audio pair is not ground referenced and the control signal requires a ground signal Configure the Model 400 001 for unbalanced operation by placing jumper P3 in the UNBAL position for interoperability between the Model 400 001 and the MS39xx Series stations No changes are required to the MS39xx Series station s For Master Slave ...

Страница 17: ... and 400 002NS RigCom Stations Page 15 of 18 P Standard IOMs Current Release 42004 Instr Manuals 42004 376E docx 08 19 Figure 11 Master Slave Configuration with the Model 400 001 as Slave Figure 12 Common Line Configuration ...

Страница 18: ...as the ground reference for the control signal The audio pair is not ground referenced in a balanced system and the control signal requires a separate ground signal Configure the Model 400 001 RigCom stations and the EZ Page stations identically as balanced or unbalanced using jumper P3 on the Model 400 001 station s and jumper P5 on the EZ Page station s for interoperability between the Model 400...

Страница 19: ... 002NS RigCom Stations Page 17 of 18 P Standard IOMs Current Release 42004 Instr Manuals 42004 376E docx 08 19 Figure 15 Unbalanced Common Line Configuration Figure 16 Master Slave Balanced Configuration with Model 400 001 as Master ...

Страница 20: ...0 002NS RigCom Stations Page 18 of 18 P Standard IOMs Current Release 42004 Instr Manuals 42004 376E docx 08 19 Figure 17 Master Slave Balanced Configuration with Model 400 001 as Slave Figure 18 Balanced Common Line Configuration ...

Страница 21: ... of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of the services provided hereunder Warranty Periods Every claim by Buyer alleging a defect in the goods and or services provided hereunder shall be deemed waived unless su...

Отзывы: