![Hubbell GAI-Tronics 351-715 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/hubbell/gai-tronics-351-715/gai-tronics-351-715_manual_2180286013.webp)
Pub. 42004-500C
Division 2 VoIP Page Phones—Wired and WiFi
Page 11 of 24
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-500C.docx
03/20
Table 3. Recommended Cable
Cable Use
Size
LAN
Cat5 or better UTP cable with an RJ45 connector
Power
two-conductor, No. 18 AWG is typical
Inputs
two-conductor, No. 22 AWG is typical
Output contacts
two-conductor, No. 18 AWG is typical
Speaker
two or three-conductor, No. 18 AWG is typical
Figure 7. Internal PCBA Connections
Network Cable
Connect a Category 5 or better UTP cable with an RJ45 connector between the LAN (Local Area
Network) and the VoIP PCBA (see Figure 7). The RJ45 jack is located on the underside of the VoIP
PCBA.
Power
Power-Over-Ethernet (PoE)
Connect power to the unit as indicated in the PoE equipment manual (Power Mode A, Class 0).