P
AGE
7
of 28
A
UXILIARY
P
OWERED
ADA-C
OMPLIANT
E
MERGENCY
P
HONES
Pub.
42004-378A
d:\standard ioms - current release\42004 instr. manuals\42004-378a.doc
05/06
Models 293-101, 293-101AL, and 294-101AL
The mounting and wiring instructions for Models 293-101, 293-101AL and 294-101AL are as follows:
1.
Remove the four tamper-resistant screws from
the front panel.
2.
Position the enclosure on the mounting
surface. The enclosure provides four
0.28-inch mounting holes. Secure it with the
four ¼-inch diameter bolts of the appropriate
length for the mounting surface.
N
OTE
:
When using the GAI-Tronics Model
231 Pole Mounting Kit, follow the mounting
instructions provided in the kit.
3.
For Model 293-101 only: Create an access
hole using a Greenlee-type punch that is
equivalent in size to the conduit diameter.
Bottom entry is strongly recommended. Insert
a conduit fitting in the access hole. Refer to
conduit installation details on page 6.
N
OTE
:
Use silicone sealant or equivalent
around and inside all conduit entries.
4.
Pull the telephone line and power supply cord through the conduit.
5.
Connect the power supply 4-pin connector to the P17 header jack on the PCBA.
6.
Connect the telephone’s modular plug to a USOC RJ11 or CA11A (Canada) modular jack.
N
OTE
:
A modular jack may be mounted inside the telephone. Connecting the telephone line directly
to TB1 is acceptable.
7.
Perform the initial programming of the phone. Refer to the Programming section on page 15.
8.
Make hardware configuration changes, if necessary. Refer to page 12 for more information. Verify
the phone is operating properly by calling to and from another phone.
9.
Adjust the speaker levels if necessary. See the Audio Level Adjustments section on page 14 for
details.
10.
Complete the installation by attaching the front panel assembly to the rear enclosure using the four
tamper-resistant screws.
Figure 5. Model 293-101 Emergency Phone in a