Confidentiality Notice .....................................................................................................................1

 

General Information .......................................................................................................................1

 

System Types ........................................................................................................................................... 2

 

Single System (Standalone) .................................................................................................................. 2 
Hot Standby (N+1) System ................................................................................................................... 2 
Duplicate (A/B) System ........................................................................................................................ 2 

Important Safety Instructions................................................................................................................ 3

 

Front Panel Indicators & Control ......................................................................................................... 3

 

Rear Panel Connections ......................................................................................................................... 4

 

Internal Connections .............................................................................................................................. 5

 

Installation ......................................................................................................................................6

 

Installation Safety Guidelines ................................................................................................................ 6

 

Installation Guidelines ............................................................................................................................ 6

 

Mounting .................................................................................................................................................. 6

 

Field Connections ...........................................................................................................................6

 

Input Power ............................................................................................................................................. 6

 

Fuses ......................................................................................................................................................... 7

 

Earth ........................................................................................................................................................ 7

 

Power Out ................................................................................................................................................ 7

 

Amplifiers ................................................................................................................................................ 7

 

Generic Amplifier Interface (GAI) ........................................................................................................ 8

 

Network .................................................................................................................................................... 9

 

Analog PABX Connection ...................................................................................................................... 9

 

API (Access Panel Interface) .................................................................................................................. 9

 

A/B Link ................................................................................................................................................. 10

 

Input/Output Modules .......................................................................................................................... 11

 

Aux Audio 1 ........................................................................................................................................... 12

 

Aux Audio 2 ........................................................................................................................................... 13

 

Operation .......................................................................................................................................13

 

Содержание GAI-Tronics 013-02-0095-005

Страница 1: ...1 System Types 2 Single System Standalone 2 Hot Standby N 1 System 2 Duplicate A B System 2 Important Safety Instructions 3 Front Panel Indicators Control 3 Rear Panel Connections 4 Internal Connecti...

Страница 2: ...LEDs 13 Telephone Access 14 Reference Documentation 14 Specifications 14 Electrical 14 System Limitations Maximums 15 Power Amplifier Audio Outputs 15 A B Interlink 15 Audio Outputs Event Record A B...

Страница 3: ...ation The Model 013 02 0095 005 and 013 02 0095 006 E3 System Controllers are central components in Elemec3 PAGA public address and general alarm systems They are for use where failsafe operation is i...

Страница 4: ...s Connect up to 16 wired access panels for speech broadcasts and manual alarm emergency message activation Additional audio inputs outputs are available to accommodate connections to from ancillary eq...

Страница 5: ...s been damaged in any way This includes but is not limited to power supply cord or plug damage exposure to rain moisture or liquid intrusion into the equipment the equipment has been dropped or has su...

Страница 6: ...6 P Standard IOMs Current Release 42004 Instr Manuals 42004 563A docx 01 21 Rear Panel Connections Make all system connections at the rear of the E3 system controller see Figure 3 US C LISTED U US C L...

Страница 7: ...1 21 Internal Connections All internal connections are plug and socket connections The following figures show the internal components of the two controller models Figure 4 Model 013 02 0095 005 System...

Страница 8: ...isconnect power before servicing Do not disconnect the equipment while the circuit is energized Avoid servicing the unit during electrical storms Do not touch uninsulated wires Installation Guidelines...

Страница 9: ...ss panel Earth Install an appropriately sized green yellow sheathed conductor between the DC EARTH terminal on the rear of the unit and the telecoms earth bar inside the cabinet see Figure 3 Power Out...

Страница 10: ...plifier Connection Generic Amplifier Interface GAI Connect up to 16 generic amplifier interfaces to an E3 system controller The GAI allows connection of alternate amplifiers not specified above for us...

Страница 11: ...e audio channel shared by the connected access panels Only one access panel has access to the audio channel at a time When more than one access panel requests access to the audio channel the panel wit...

Страница 12: ...the B controller via the A B LINK module per the drawing below see Figure 9 1 Install the IDC ribbon cable between the A B LINK header of the A controller and header CONA of the No 999 02 3003 00X A...

Страница 13: ...with this controller Table 3 Input Output Modules Model Description Inputs Outputs 030 02 0095 000 Elemec3 Generic I O 16 Inputs 0 Outputs 030 02 0095 004 Elemec3 Generic I O Relay 1 16 Inputs 4 Outp...

Страница 14: ...em interface Install a 20 conductor IDC ribbon cable between the AUX AUDIO 1 port on the controller see Figure 3 and the 20 conductor IDC interface PCBA see Table 4 for the termination pin out informa...

Страница 15: ...peration Each E3 system controller receives a custom configuration for its specific application via the Elemec3 Console and Elemec3 Portal applications Please refer to the Elemec3 system manual includ...

Страница 16: ...d operation Telephone Access 1 To make a broadcast over the PA system 2 Dial the extension allocated in the IP PBX to the Elemec3 VoIP telephone interface The system transmits a confidence tone to the...

Страница 17: ...2 0095 003 only 1 Page Party Interface 1 A B Controller Link 1 USB Port not functional PowerAmplifier AudioOutputs Isolation 500 V RMS Output Level 0 775 V rms at 1 kHz 17 maximum load Bandwidth 200 H...

Страница 18: ...ower out 24 V dc out two pin plug with screw terminals Minimum conductor size with ferrule 0 25 mm2 Ethernet LAN RJ45 jack USB Host Port USB USB Type A Receptacle Access Panel Interfaces AP1 4 AP5A 5B...

Страница 19: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...