Euclid Lifting Magnet Controllers: Automatic Discharge

Specifications 4291

period, controlled by the Potentiometer (P1) 
assembly,   the   DSM   de-energizes   the   Drop 
Relay.     This   causes   the   Drop   contactor   to 
open and end the reverse current cycle.
The remaining reverse magnet current flows 
through a secondary discharge path from the 
magnet through the normally closed "power 
auxiliary" interlock of 2L, the DVA and back 
to the magnet.
The Euclid magnet controller can be operated 
by a small notched position master switch or 
a maintained contact-type pushbutton station.

The  arrangement  of  the   circuit  components 
allows an operator to drop portions of a load 
with ease.   This is a feature most operators 
will appreciate.  A portion of the load can be 
dropped by merely moving the master switch 
only  the distance necessary to momentarily 
de-energize the "Lift" contactor.  This feature 
is possible because of the permanently con-
nected discharge path and the elimination of 
having to close the "Drop" contactor before 
opening the "Lift" contactor.

FANNING PACKAGE

 includes Fanning Con-

tactor   and   Fanning   Resistor   for   separate 

mounting   suitably   enclosed   for   NEMA   2   or 
NEMA 3R service.
Fanning   is   the   insertion   of   a   resistor   dis-
charge path in parallel with the DVA to give 
extended magnet discharge time that is acti-
vated by a separate fanning pushbutton.  The 
operator is allowed to control the rate of mag-
net discharge, dropping all or part of the load, 
by activating the fanning control.   Releasing 
the fanning  pushbutton deactivates the  fan-
ning control and returns the magnet controller 
to the lift mode to retain the remaining mag-
net load.

Comparison ChartSchematic Diagram

Schematic Diagram

Symbol

Function

Symbol

Function

DR

DROP RELAY

MOV

SURGE SUPPRESSOR

PI

POTENTIOMETER ASSEMBLY

DVA

DISCHARGE VARISTOR

CFU

CONTROL FUSE

DSM

DISCHARGE SENSOR MODULE

RFU

DROP FUSE

D

DROP CONTACTOR

DI

DIODE

2L

LIFT CONTACTOR

RECT

RECTIFIER, MAGNET DISCHARGE PATH

1L

LIFT CONTACTOR

Page 2 of 4