background image

P303-1466

Rev. B

INSTRUCTIONS 

FOR

© Copyright 1996 & 2013 Hubbell Incorporated

CHANCE PISA

®

 LOCKING DOG ASSEMBLY

NOTE: Hubbell has  a policy of continuous product improvement. We reserve the right to change design and specifications without notice.

GENERAL

These instructions do not claim to cover all details or variations in equipment, nor to provide for all possible conditions to be 

met with concerning installation, operation, or maintenance of this equipment. If further information is desired or if particular 

problems are encountered which are not sufficiently covered in this guide, contact Hubbell Power Systems.

 WARNING

Anchor installation can puncture underground utility service.
Can cause property damage, serious injury, or death.
Locate and avoid all underground-utility services before 

installing an anchor.

Bolt the Locking Dog Assembly to the Kelly Bar Adapter 

(a Torque Indicator may be inserted between them) using 

the bolts, lockwashers, and nuts provided (both must have 

the same size bolt circles or a Bolt Circle Adapter must be 

used). The bolts provided with each Locking Dog Assembly 

are hot dip galvanized, and are the appropriate length for 

attachment to another flange of equal thickness with clear

-

ance holes (not tapped holes).
Tighten the bolts to the recommended torque values shown 

in the table on the right.
Note: Galvanized bolts cannot be used to attach the 

adapter to another tool having tapped holes (such as the 

Chance Torque Indicator). When using a Torque Indicator 

use the plated bolts provided with the Torque Indicator to 

attach the Kelly Bar Adapter and Locking Dog Assembly 

and tighten to the recommended torque values shown in 

the table on the right.

Read, Follow,  and Understand this instruction sheet completely 

before installing an anchor. These instructions are intended to 

illustrate the use of Locking Dog Assembly. Anchor installing 

tools covered in this instruction sheet must be used by com-

petent personnel familiar with and following good work and 

safety practices. Should additional information and details be 

desired, or if specific situations arise which are not covered 

adequately herein, the user should refer to Chance directly.  

In some cases, Chance may make specific recommendations 

concerning installation torque and installation depth for a 

particular application. 

 WARNING

If necessary to replace any bolts, always replace with the 

same diameter, length, and grade as the originals.

Torque 

Rating of 

the Anchor 

tools (ft-lb)

Bolt Circle 

Diameter

Bolt 

Dia.

Grade

Recom-

mended 

tightening 

dry torque 

values (ft-

lb) on bolts

10,000

5-1/4"

1/2

5

75

15,000

7-5/8"

5/8

2

95

KELLY BAR

COIL LOCK

BENT ARM PIN

LOCKING DOG

ASSEMBLY

Отзывы: