For warranty see http://www.hubbelllighting.com/resources/warranty
© 2015 KIM LIGHTING
16555 E. Gale Ave., City of Industry, CA 91745-1788, 626-968-5666, FAX: 626-330-3861
SWIVEL ADJUSTMENT
PAGE 2
1.
Loosen set screw to adjust fixture
rotation, then tighten the set screw.
2.
To adjust backtilt up to 60° maximum,
loosen swivel screws being careful not
to disengage threads. Hold fixture at
desired angle and firmly tighten swivel
screws.
4300 Sign/Wall Lighter LED with PicoPrism
™
Installation Instructions
Fixture
Housing
30 mA Max
Gray Dimming Lead (-)
Standard Input Black (+)
White (-)
Green (GND)
Purple Dimming Lead (+)
Driver has a 0-10V dimming interface with a
dimming range of 10-100%. Is compatible
with most control systems including Hubbell
Building Automation wiHUBB
™
. Approved dim-
mers include Lutron Diva DVTV, Lutron Nova
NFTV and NTFTV. Note: Not compatible with
current sourcing dimmers. Controls compatible
via Gray and Purple dimming lead.
0-10V Dimming
6.
Attach fixture onto coupling. Support
opposite end by attaching swivel to
rigid pipe of appropriate length for
site local soil conditions. Remove
protective paper from lens.
J-Box
Support Pipe
(By Others)
Do not aim fixture down unless
protected from direct water spray.
60°
MAX.
backtilt
60°
MAX.
backtilt
60°
MAX.
Down
Do not exceed 60° backtilt aiming.
Do not aim fixture down unless
protected from water spray