background image

 

© 2014 KIM LIGHTING    

16555 E. Gale Ave., City of Industry, CA  91745-1788,  626-968-5666,  FAX: 626-330-3861

PAGE 2

B30-LED Series 8” Round Traditional Bollard 

Installation Instructions

FOR OPTIONAL BATTERY BACKUP

Driver assembly and base casting looks 

like image above. Connect the circuit 

ground wire to the green wire connected 

to the green wire connected to the 

grounding lug lead on the driver bracket. 

Connect the power supply leads to the 

driver input leads, white-to-common and 

black-to-voltage, black “Un-switched to 

AC Power” lead to an un-switched AC 

power source of 100-277V AC. 

 

Fixture

Housing

30 mA Max

Gray Dimming Lead (-)

Standard Input Black (+)

Unswitched Input Black (+)

White (-)

Green (GND)

Purple Dimming Lead (+)

BATTERY BACKUP 

If your fixture includes Battery Backup 

Option, an additional power wire is included 

labeled “Unswitched Power”. This lead must 

be connected to an unswitched power 

source running 120-277 VAC to function 

properly.

0-10V DIMMING 

Driver has a 0-10V dimming interface with 

a dimming range of 10-100%. Is compat-

ible with most control systems including 

Hubbell Building Automation wiHUBB

Approved dimmers include Lutron Diva 

AVTV, Lutron Nova NFTV and NTFTV. Note: 

Not compatible with current sourcing dim-

mers. Controls compatible via Gray and 

Purple dimming lead.