3, color sensor coordinate titration end point detection, judgment and reliable end

conditions.

4, don't need to waste liquor cup.

5, extract and neutralization liquid by a peristaltic pump control, high measuring

accuracy.

6, history inquiry, instruments and automatic memory function, with the result of the

experiment time automatic storage of record, and is not lost the data after power off, can

be stored for more than 10 years, for later queries to print.

7 calendar clock, temperature compensation, as accurate, record the date and time,

determination in power to run more than 10 years;

8, with special reagent bottle holding extract and neutralization liquid, reagent in use

process not exposed to air, avoid the influence of solvent evaporation and CO2 in the air;

Users don't have to hand contact with solvents, reducing the organic solvents and

chemicals to the harm of human body.

9, the equipment is simple operation, using large screen LCD and Chinese menu

options, users only need to choose the menu function, according to the relevant data of

the screen prompts, the instrument can automatically complete the determination of acid

value.

10, the tester still can choose according to need only one sample or continuous

measurement of 2-6 sample.

11, convenient communication with the computer with RS232 interface.

12, micro printer, thermal makes printing more beautiful and more quickly, with offline

print function.

III.Technical Parameters

1, the power supply voltage: AC220V plus or minus 20% to 50 hz + 10%

2, determination of acid value range: 0.0001 to 0.5000 mgKOH/g

The minimum resolution: 0.0001 mgKOH/g

Accuracy: acid value between 0.001 0.1000 mgKOH/g,

Allowed error range: 0.02 mgKOH/g

Содержание HZCS-X6

Страница 1: ...HZCS X6 Automatic Oil Acidity Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Страница 2: ...nical Parameters 2 IV Instrument Structure 3 V Menus and Buttons Operation Instructions 4 VI Out of The Installation 12 VII Test Steps 12 VIII Use the Matters Needing Attention 13 IX Failure Phenomeno...

Страница 3: ...uitable for the detection of transformer oil turbine oil and fuel resistance acid value of the sample analysis of measurement The product through mechanical optical and electronic technology integrate...

Страница 4: ...n and CO2 in the air Users don t have to hand contact with solvents reducing the organic solvents and chemicals to the harm of human body 9 the equipment is simple operation using large screen LCD and...

Страница 5: ...ent is divided into three parts namely control box mechanical transmission parts test area Test area is placed in the oil cup wheel number of drops of detection device automatic determination of acid...

Страница 6: ...ument becomes simple Instrument is divided into four display welcome boot images parameter Settings screen history picture sample pictures Detailed below 1 the boot screen Connect good instrument powe...

Страница 7: ...nt factory has been calibrated no special circumstances do not easily into the calibration Remember that If the boot without touching the cross cursor after 2 seconds automatically enter the boot welc...

Страница 8: ...e current parameter values press save to save parameters press exit button to return to the boot screen The meaning of each parameter stated below Date time instrument of the system clock Print mode i...

Страница 9: ...minimum record number is 1 Print print the current history records the printing content including 1 sample to 6 of the sample determination results the inspection date and time Del delete the current...

Страница 10: ...ation national standard and concentration in 0 02 to 0 05 moL L if and the concentration of the night and showed inconsistent by neutralizing night concentration increase and decrease the Numbers belo...

Страница 11: ...experiment process with sample determination 3 Cur Hue is value of the color sensor automatic detection and display instrument 4 End Hue experimental basis of titration end point is refers to the test...

Страница 12: ...Note if you quit is not to continue the line experiments please cleaning operations or you can press SKIP exit Sample test used to determine the acid value of crude oil sample After open the oil cup...

Страница 13: ...on to adjust parameters as shown in the figure below After all the input press the RUN key are measured and the process used in the determination of the Test result column indicates display informatio...

Страница 14: ...e will automatically blank experiment operation note to observe the neutralization liquid titration speed about every drop 1 seconds and then will finish cup to take out the blank experiment experimen...

Страница 15: ...when the ambient light is consistent before and after the test 5 experimental oil cup cup dish the pallets must ensure that the bottom is completely inside the cup in order to avoid cup set is not st...

Страница 16: ...rinter paper began to walk After the front end of the printing paper cut into triangles printing paper into the printer back into paper printing paper will be involved in printer Typed to stay out of...

Отзывы: