background image

4

Technical index

Accuracy

(Reading X 0.2%+2

words)

Maximum
resolution

0.1µΩ

Conditions of use and appearance

Working power

supply

Built in lithium battery or external charger, charger input 100

240VAC, 50HZ/60HZ

Charging voltage

16.8V

Charging

current

≤3A

Charging time

About 4 hr

Use time

More than 8 hr

Host weight

1.6 kg (Test line is not

included)

Dimension

246mm(L)X 156mm(W) X

62mm(H)

Use of

temperature

-10

℃~

50

relative

humidity

≤90%

No dew

VI.Adjust The Wristband

For better grip, strip the belt and adjust the adhesive tape as shown in the following

figure.

VII.Battery Charging

When the battery is low after long storage or before the first use of the handheld device,

please use the charger attached to it to charge the battery for at least 2 hours, and

continue to use the hand-held tester when charging. When the battery is fully charged,

the charger light changes from red to green.

VIII.Tilt Hand-held Tester

In order to take the instrument or expose the side interface during operation, the

hand-held tester can be tilted, as shown in the figure below.

Содержание HZ-3110E-I

Страница 1: ...HZ 3110E I Portable DC Winding Resistance Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Страница 2: ...manual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this...

Страница 3: ...aging Content 2 IV Functional Characteristics 3 V Technical Indicators 3 VI Adjust The Wristband 4 VII Battery Charging 4 VIII Tilt Hand held Tester 4 IX Product Appearance 5 X Operation Instructions...

Страница 4: ...nt or battery fails please return to the factory II Introduction Portable DC Winding Resistance Tester is an innovative product with compact size hand held operation more portable and easy to carry Th...

Страница 5: ...ected which is convenient and fast Wide range and high accuracy 500u 50K It has the function of resistance temperature conversion and can be equipped with wireless temperature measurement module which...

Страница 6: ...90 No dew VI Adjust The Wristband For better grip strip the belt and adjust the adhesive tape as shown in the following figure VII Battery Charging When the battery is low after long storage or befor...

Страница 7: ...5 Lift the tilt seat and pull outward IX Product Appearance Top view...

Страница 8: ...surement signal reception Display 5 6 inch large industrial high brightness color LCD screen display operation menu and test results button Operate instruments is the up and down key select to move or...

Страница 9: ...ischarge protection when the instrument is low power the charger can be plugged in to charge and the instrument can be used normally in the charging process Instructions for use of printer The key of...

Страница 10: ...ress Enter to enter the corresponding menu DC resistance test function can measure transformer mutual inductor reactor and other inductive test products and copper bars conductors switch contacts and...

Страница 11: ...emperature Setting the measured resistance value needs to be converted to the temperature value The converted temperature value is 0 255 which is related to the accuracy of the converted resistance va...

Страница 12: ...on and press the Cancel button to return to the previous screen Retest according to the current settings parameters Print the current test results by connecting the external printer Save the current t...

Страница 13: ...11 In the process of testing transformers the unmeasured side winding must be opened XII Packing List No Item Qty 1 Main engine 1 2 Power line 1 3 Red test line 1 4 Black test line 1...