background image

11

2. AE measurement:

The AE sensor at the front of host shall be aimed at the gap of the measured equipment and

observe along the gap if the AE data and waveform changes, then read and record the data.

3. TEV external synchronization measurement:

External synchronization module can be added for testing when finding the suspicious

discharge signals and further measurements are needed. And then check the synchronization of
waveform and the Q-

Φ

-T diagram. The figure below shows the relation between the quantity of

electricity, phase and time.

Select the external synchronization in parameter settings, and red rectangle-frame prompt will

appear in the state indicator bar upside the equipment; then the external synchronization module
shall be connected with the 220VAC of the same power of the measured equipment. Then the signal
output end of the module is connected with the external synchronization interface of the main
engine using the special signal line; the red prompt rectangle in the state indicator bar upside the
equipment will disappear. The main engine shall be perpendicular to the surface of the equipment
being tested so that the front-end TEV sensor can place on the surface of high-voltage equipment,
and then test the suspicious discharge locations to observe the changes of data and waveform as
well as Q-Φ-T diagram with cooperation of synchronous frequency regulation, and then further
analysis and judgement are carried out to determine whether it is a discharge signal.

Содержание HZJF-9008

Страница 1: ...HZJF 9008 Handheld Partial Discharge Detector USER MANUAL Huazheng Electric Manufacturing Baoding Co Ltd...

Страница 2: ...age or data loss The product may contain the terms Danger when doing this it may hurt you Warning when doing this it may cause potential dangers to you Attention when doing this it may cause damage to...

Страница 3: ...dates the latest version is applicable to this standard GB T 2423 Environmental test of electrical and electronic products GB T16927 High voltage test technology GB T 17626 Electromagnetic compatibil...

Страница 4: ...t this product fails please contact our maintenance staff for inspection Any maintenance and adjustment must be carried out by the maintenance staff of our company Please keep the product surface dry...

Страница 5: ...ent interface 4 3 TEV pulse count measurement interface 4 4 AE partial discharge measurement interface 5 5 Parameter setting interface 5 6 Data storage query playback and synchronization frequency set...

Страница 6: ...esolution 320 x 240 Sensor Built in AE TEV External interface AE TEV external interface external synchronization interface headphone jack Micro SD card 16G charging port USB port Backup Interface exte...

Страница 7: ...ression function 11 alarm threshold setting and indicating function partial discharge alarm indication the color indicator bar at right side tap shift indication suggest shifting tap in case of red ba...

Страница 8: ...ey 5 power key As shown in the figure above long press the power key on the lower left corner of the keypad panel to enter the self checking screen as the figure below after successful self checking t...

Страница 9: ...ts sensor measurement mode and gain display partial discharge indicating value current value maximal value in turn finger print diagram tendency chart oscillogram partial discharge warning diagram dis...

Страница 10: ...ce by press the menu key on TEV partial discharge measurement interface press the up and down keys to select the sensor settings and press the left key to switch to AE sensor after choosing the save e...

Страница 11: ...o adjustment is needed in the test process 5 alarm threshold this default value is recommended and no adjustment is needed in the test process 6 calibration quantity this default value is recommended...

Страница 12: ...ace press the up and down keys to switch to the data storage menu after determining the number of equipment press the OK key to store the current data into SD card it will prompt date is being saved t...

Страница 13: ...terface Then press the left and right keys to adjust the value it will be found that the real time waveform gradually slows or stops indicating that the synchronization frequency is consistent with th...

Страница 14: ...r 7 2 Partial discharge indicating value Fig 7 2 partial discharge indicating value The current partial discharge indicating value and the maximum partial discharge indicating value are shown in the f...

Страница 15: ...e early warning and red represents warning VI Introduction of partial discharge measurement The measurement method of HZJF 9008 handheld partial discharge detector is simple the equipment needs no rec...

Страница 16: ...the state indicator bar upside the equipment then the external synchronization module shall be connected with the 220VAC of the same power of the measured equipment Then the signal output end of the m...

Страница 17: ...l discharge patrolling measurement instrument embedded software 1 set 3 HZJF 9008 External synchronization module and twin core power line 1 set 4 Charger and twin core power line 1 set 5 Outer synchr...