6. Specification

 Figure 15 Inputting Inverter S/N through A Webpage

09

Communications Interface 

Communication with Microinverter 

Ethernet

USB 

Monitoring Capacity 

Human Interface 

Display 

Power Requirements 

Mechanical Data 

Features 

Standard Warranty Term 

Compliance

Power Consumption 

AC Inlet 

HY-MDL

HY-MDL-3

Power Line Communication 

10/100 auto-sensing, auto-negotiation

USB 2.0 interface, auto-sensing, auto-negotiation

-40˚C to +55˚C (-40˚ to 131˚F)

Natural convection – no fans

Indoor - NEMA 1 

1 year

UL 60950-1 2nd Edition Rev Dec 19, 2011

CSA C22.2 2nd Edition Rev Dec 19, 2011

FCC Part 15 Class B

AS/NZS 60950.1:2011 Inc A1

AS/NZS CISPR 22: 2009+A1:2010

EN 60950-1:2006+A11:2009+A1:2010+A12:2011

EN 55022:2010

EN 61000-3-2:2006+A1:2009+A2:2009

EN 61000-3-3:2008

EN 55024:2010

EMC Directive 2004/108/EC

255 micro inverters 

5-in LCD touch screen

7-in LCD touch screen

Dimensions (WxHxD)

Weight 

Ambient Temperature Range 

Cooling 

Enclosure Environmental 

6.69” x 4.33” x 1.46”

150g

720g

7.83” x 6.34” x 1.81”

5 watts maximum

8 watts maximum

100 - 240 Vac, 50/60 Hz

Содержание HY-MDL

Страница 1: ...Installation and Operation Manual HY MDL HY MDL 3 For our home energy independence Huayu Ningbo New Energy Technologies Co Ltd...

Страница 2: ...Use This Manual 4 User Interface 03 03 4 1 Main Interface 03 4 2 Interface Overview 04 4 3 Energy Functions 06 4 4 Setting 07 4 5 Backup Clear Data 08 4 6 Status Bar 02 2 FCC Compliance 3 Installation...

Страница 3: ...al Management Platform with over 10 languages these innovative technologies are developed to configure a Smart Distributed Solar System with bidirectional flow of energy which no doubt is the basic in...

Страница 4: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there...

Страница 5: ...r at the lower part of the screen The tool bar contains 7 buttons Save Clear Backup Restore Factory Defaults Summary Display Summary Display Interface Today s Energy Current Day Power Generation 7 Day...

Страница 6: ...20 00 and the y axis represents Huayu micro inverters output power kW The total output energy kWh is displayed on the upper left corner The real time output power kW and today s total energy generated...

Страница 7: ...r the last 12 months see Figure 8 This display is similar to the Last 7 Days Energy display The x axis represents months and the current month is in the last The y axis represents the amount of energy...

Страница 8: ...ications address settings tab Figure 12 is used to set the power line communication address of the micro inverters linked to the device One HY MDL HY MDL 3 monitoring data logger can monitor up to 255...

Страница 9: ...n and press Yes on the confirmation window that appears to clear all collected data The device settings will not be changed The bottom field on all display pages consists of the status bar which displ...

Страница 10: ...through Huayu Portal from anywhere at anytime To access the web portal inside HY MDL HY MDL 3 user only needs to type in the IP address of HY MDL HY MDL 3 on a web browser please see Section 4 4 1 for...

Страница 11: ...auto sensing auto negotiation 40 C to 55 C 40 to 131 F Natural convection no fans Indoor NEMA 1 1 year UL 60950 1 2nd Edition Rev Dec 19 2011 CSA C22 2 2nd Edition Rev Dec 19 2011 FCC Part 15 Class B...

Страница 12: ...Huayu Portal Mobile App Tel 86 574 8925 8801 Add No 456 Xingning Road Ningbo 315100 P R China E mail info huayu energy com Website www huayu energy com...

Отзывы: