Table 2-7 Disk indicators
Indicator
State Description
Disk fault indicator
● Off: The disk is operating properly.
● Blinking yellow: The disk is being located, or the
RAID is being reconstructed.
● Steady yellow: The disk is faulty, or a member disk in
the RAID array is faulty.
Disk activity indicator ● Off: The disk is not detected or is faulty.
● Blinking green: Data is being read from the disk,
written to the disk, or synchronized between disks.
● Steady green: The disk is inactive.
2.7 Fan Modules
The X6000 uses four 8080 counter rotary fans with high wind pressure to improve
the cooling capability of the server. The management module adjusts the fan
speed based on the server node operating status to implement intelligent heat
dissipation, and one-fan failures are allowed.
shows a fan module.
Figure 2-9 Fan module
2.8 PSUs
An X6000 is equipped with two AC or 240 HVDC PSUs.
TaiShan X6000 Server
User Guide
2 Components
Issue 04 (2020-06-05)
Copyright © Huawei Technologies Co., Ltd.
15