Table 5-1
IP address planning
Name
IP address
Subnet mask
Gateway address
SC
200.53.24.11
255.255.0.0
200.53.0.1
Computer / Data
Base
200.53.24.11
255.255.0.0
200.53.0.1
8650C
200.54.1.101
255.255.0.0
200.54.0.1
shows the participant data planning.
Table 5-2
Participant data planning
Site Name
Terminal Number Other Information
Site1
0100001
Device type: Terminal
Site type: IP
Rate: 768 kbit/s
Password: 123456
Contact: Rose
Telephone: 01087654321
Email: [email protected]
The Email notification function is not
enabled.
Site2
0100002
Site3
0100003
Define each IP terminal as an IP participant on the RM and an endpoint on SC respectively.
The IP terminal, IP participant, and endpoint are associated by the same terminal number. The
IP participant should meet the following requirements:
Terminal number: The parameters on the RM (terminal number of the IP participant), the
SC (Endpoint number) and the terminal (terminal number) must be consistent with each
other.
Terminal password: If the SC adopts the password authentication, the terminal password
of the IP participant defined on the RM, the node password defined on the SM, and the
registration password of the IP terminal should be the same.
5.1.2 Configuring the Parameters Between the 8650C MCU and
the RM
To use a terminal to hold a conference with the RM, the SC, and the MCU, you need to set the
connection parameters for the MCU and the RM.
Step 1
Log in to the 8650C web interface.
Step 2
Choose
Settings
>
System
>
RM Connection
.
The
RM Connection
page is displayed, as shown in