Indicator
State Description
Transmission rate
indicator
l
Steady green: The data transmission rate is
10 Gbit/s.
l
Steady yellow: The data transmission rate is
lower than 10 Gbit/s.
l
Off: The network port is not connected.
GE
electrical
port
Connection status
indicator
l
Steady green: The network port is properly
connected.
l
Off: The network port is not connected.
Data transmission status
indicator
l
Blinking yellow: Data is being transmitted.
l
Off: No data is being transmitted.
UID indicator
The UID indicator helps identify and locate a
server. You can turn on or off the UID indicator
by pressing the UID button or remotely running
a command on the iBMC CLI.
l
Steady blue/Blinking blue: The server is
being located.
l
Off: The server is not being located.
PSU indicator
l
Steady green: The power input and output
are normal.
l
Steady orange: The input is normal, but no
power output is supplied due to overheat
protection, overcurrent protection, short
circuit protection, output overvoltage
protection, or some component failures.
l
Blinking green at 1 Hz:
–
The input is normal, the server is standby,
and the PSU is in MV6 mode. (The
output voltage is 6.7 V.)
–
The input is overvoltage or undervoltage.
–
The PSU is in deep hibernation mode.
l
Blinking green at 4 Hz: under online
firmware upgrade.
l
Off: No AC power is supplied.
2.5 Flexible NIC
Supported flexible NICs include:
l
SM211 (chip: i350) with two GE electrical ports
l
SM210 (chip: 5719)/SM212 (chip: i350) with four GE electrical ports
l
SM233 (chip: X540) with two 10GE electrical ports
2288H V5 Server
User Guide
2 Components
Issue 04 (2018-09-04)