A
Appendix
A.1 Cable
This section describes the PGND cable, power cable, configuration cable, Ethernet cable, and
optical fiber of the USG.
A.1.1 PGND Cable
This section describes the structure and specifications of the protection ground (PGND) cable
for you to ground the USG. Read this section before you make or purchase any PGND cables
for the USG.
The PGND cable is used in the following situations:
l
The USG is installed inside the cabinet.
If the cabinet has been properly grounded, connect one end of the PGND cable to the
ground terminal of the USG and the other end to the ground port of the cabinet.
l
The USG is installed outside the cabinet.
Connect one end of the PGND cable to the ground terminal of the USG and the other end
to the ground bar in the equipment room.
NOTICE
Unreliable grounding may damage the USG. Therefore, ensure that the USG is reliably
grounded during operation.
Structure and Appearance
A PGND cable has two OT bare crimp terminals and a copper cable with yellow/green plastic
encapsulation.
shows the appearance of a type of PGND cables.
NOTE
The figure is for reference only.
HUAWEI USG6000 Series
Hardware Guide
A Appendix
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
371