U8655
Maintenance Manual
9 Principles and Failure Analysis
Issue 1.0 (2012-02-23)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
27
The PM8029 provides two types (switched-mode power supply and LDO regulators) of
programmable voltage regulators with a total of 24 output channels.
The follow table lists the voltage regulator parameters.
Table 9-2
Voltage regulator specifications
Troubleshooting Process
To troubleshoot the power-on failure, firstly check whether the I/O connector (battery
connector) is damaged. If the I/O connector (battery connector) is not damaged, use a DC
regulated power supply to supply power to the phone, and test the phone's current.
The power-on failure may be caused by any of the following conditions:
No current