TP48200A-DT19C1, TP48200A-DT19C2,
TP48200A-HT19C1 and TP48200A-HT19C2 Telecom
Power
User Manual
4 Maintenance
Issue 03 (2019-11-15)
Copyright © Huawei Technologies Co., Ltd.
81
4.4.10 Replacing a TEC
Prerequisites
You have obtained an ESD wrist strap, a pair of ESD gloves, an ESD box or bag, and the
cabinet door key.
The new TEC is intact.
Context
You only need to disconnect the power supply to the TCUA control box, but do not need to
disconnect the AC input to the power system.
Procedure
Step 1
Connect the ground cable to the ESD wrist strap, and put on the ESD wrist strap and ESD
gloves.
Step 2
Remove the TEC control box.
1.
Switch off the circuit breaker (F10) for the TCUA control box on the DC PDU.
2.
Record positions where cables connect to the TCUA control box and disconnect the
cables.
3.
Unscrew and remove the TCUA control box, as shown in Figure 4-20.
Step 3
Remove the TEC.
1.
Record the position where the TEC cable connect to the TCUA control board, and
disconnect the cable.
2.
Unscrew and remove the external cover from the cabinet door, as shown in Figure 4-22.
3.
Unscrew and remove the TEC, as shown in Figure 4-23.