2.1 Checking the Software Version
This topic describes how to check whether the current software version meets the deployment
requirement.
Prerequisites
You must be logged in to the MA5616. For details about how to log in to the device, see
Configuring the Maintenance Terminal
.
Procedure
l
The procedure of checking the software version through the MA5616 is as follows:
1.
In the user mode, run the
display language
command to check whether the multi-
language information supported by the system and the system version meet the
deployment requirement.
2.
In the user mode, run the
display version
command to check whether the versions of
the host software and patch that is running in the system meet the deployment
requirement.
l
The procedure of checking the software version through the iManager U2000 is as follows:
1.
In the
Workbench
window, double-click
. The
Main Topology
window is
displayed. Click
.
2.
In the
Search
dialog box, select
NE
from the
Search Type
drop-down list and enter
the description of the MA5616 to be queried. Then, click
Search
.
3.
In the search result, select the desired MA5616. Click
Locate
and select
Locate to
NE Panel
from the list. In the
Device Detailed Info
tab page, verify that the device
type and activated patch meet the deployment requirement.
----End
Result
l
The versions of the host software and patch meet the deployment requirement.
l
If the versions do not meet the deployment requirement, contact Huawei technical support
center to upgrade the host software if necessary. For details about the upgrade, see the
MA5616
Upgrade guide
.
2.2 Checking the Board Status
This topic describes how to check whether the inserted board is the same as the board specified
in the data plan, and whether the boards are in the normal state.
Procedure
l
The procedure of checking the board status through the MA5616 is as follows:
1.
Run the
display board
command to check whether the board information (including
the board types and the slots housing the boards) meets the data plan and whether the
boards are in the normal state.
SmartAX MA5616 Multi-service Access Module
Configuration Guide
2 Checking Before the Configuration
Issue 04 (2011-10-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8