l
If the board is properly installed, go to
.
l
If the board is not properly installed, remove and insert the board, and ensure that the board
is properly installed. Then, go to
.
NOTE
If the board is not properly installed, component detection fails during board startup and therefore the
startup fails. The fault can be rectified only by removing and inserting the board.
Step 2
Check whether the fault is rectified.
l
If the fault is rectified, go to
.
l
If the fault is not rectified, go to
.
Step 3
Replace the board, wait about 5 minutes, and then check whether the new board is working
normally.
NOTE
A board is in the Auto_find state after being discovered automatically. Run the
board confirm frameid/slotid
command to verify that the board is working normally.
l
If the new board is working normally, the original board is faulty. Go to
l
If the new board is not working normally, go to
.
Step 4
Record the results of the preceding steps in a fault report (see Fault Report Form), fill out the
entire form, and then submit it to Huawei for technical support (see
Step 5
End.
----End
6.6 Repeated Board Reset
This section describes how to troubleshoot the repeated reset of a service board on the
MA5612.
Location Method
Use the following guidelines to locate the fault:
1.
Check whether the type of the board in use is the same as that configured for the system.
2.
Check whether the ambient temperature of the device is too high.
3.
Check whether the board is properly installed.
4.
Check whether the board is faulty.
5.
Check whether the backplane of the device is working properly.
6.
Check whether the board software in the system is correct.
CAUTION
l
To facilitate fault report, save the results of the following steps.
l
Take ESD measures before removing and inserting a board.