NOTE
When you paste a text to the HyperTerminal, the character delay controls the character transmit speed,
and the line delay controls the interval of transmitting every line. If a delay is very short, loss of
characters occurs. When the pasted text is displayed abnormally, modify the delay.
----End
Result
On the Hyper Terminal interface, press
Enter
, and the system prompts you to input the user
name. Input the user name and the password for user registration (by default, the super user name
is
root
and the password is
admin
), and wait until the CLI prompt character is displayed.
NOTE
To improve the system security, please modify your password after first login. You can run the
terminal
user password
command to modify your password.
If the login fails, click
and then click
on the operation interface. If the login still fails,
return to step 1 to check the parameter settings and the physical connections, and then try again.
Follow-up Procedure
l
You can run the
idle-timeout
command to set the terminal timeout time. if you do not input
commands within the specified timeout time, the system disconnects the terminal. By
default, the terminal timeout time is set to 5 minutes. If you do not run any commands
within 5 minutes, the system disconnects with the terminal. To perform any operation, you
must have to log in to the system again.
l
In the commissioning procedure, you must use the command, It is recommended that you
know well the command modes first.
shows how to switch command modes.
Figure 1-12
huawei(config)#
huawei(config-if-...)
interface
quit
huawei#
huawei>
enable
config
disable
quit
quit
return
Login
User mode
Privilege mode
Global config mode
Interface/config mode
1.3.5.2 Login Through Telnet (Outband Management)
This topic describes how to log in to the MA5600T/MA5603T/MA5608T using the local
maintenance Ethernet port (outband management port) in the telnet mode to maintain and
manage the MA5600T/MA5603T/MA5608T. You are advised to use SSH mode.
Prerequisites
Engineers are logged in to the MA5600T/MA5603T/MA5608T by using the local serial port or
the ETH port.
NOTE
The default IP address of the maintenance Ethernet port (ETH port on the control board) is 10.11.104.2,
and the subnet mask is 255.255.255.0.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
1 Commissioning
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
26