1.5.2 Checking Alarms and Events
This topic describes how to check the alarm and event reporting function of the device.
1.5.2.1 Verifying the Alarm and Event Function
This topic describes how to verify the alarm and event function by triggering various alarms and
events through the related operations.
Verifying Operation
lists the operations for verifying the alarm and event function.
Table 1-46
Operations for verifying the alarm and event function
Operation
Description
Remove a service board.
Check whether the corresponding alarm or event is
generated on the maintenance terminal.
Insert the service board back into the
slot.
Check whether the corresponding recovery alarm or
event is generated on the maintenance terminal.
Remove the optical fiber connected to
an optical port.
Check whether the corresponding alarm or event is
generated on the maintenance terminal.
Insert the optical fiber back into the
optical port.
Check whether the corresponding recovery alarm or
event is generated on the maintenance terminal.
Remove the optical fiber connected to
an optical port when an ONT is online.
Check whether the corresponding alarm or event is
generated on the maintenance terminal.
Insert the optical fiber back into the
optical port.
Check whether the corresponding recovery alarm or
event is generated on the maintenance terminal.
Open the cabinet door.
Check whether the corresponding alarm or event is
generated on the maintenance terminal.
Close the cabinet door.
Check whether the corresponding recovery alarm or
event is generated on the maintenance terminal.
Remove the fan tray from the shelf.
Check whether the corresponding alarm or event is
generated on the maintenance terminal.
Insert the fan tray back into the shelf.
Check whether the corresponding recovery alarm or
event is generated on the maintenance terminal.
Perform the active/standby switchover
of the control boards.
Log in to the system, and run the
display event
history
command to check whether the active/
standby switchover event history exists.
1.5.2.2 Querying Alarms and Events
This topic describes how to query history alarms and events through the maintenance terminal.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide