7.11.3 Example for Configuring VRRP Fast Switchover
Networking Requirements
, Switch A, Switch B, Switch C, Switch D and the Universal Medium
Gateway (UMG) form a simple next generation network (NGN).
The networking is as follows:
l
The UMG connects to Switch A and Switch B through Switch C and Switch D.
l
Switch A and Switch B run VRRP. Switch A functions as the master, and Switch B
functions as the backup.
When Switch A fails, or when the link between Switch A and Switch B fails, the active/standby
switchover should be completed within 1 second. That is, fast switchover is required on the
bearer network.
Figure 7-5
Networking of VRRP fast switchover
Backup group 10
Virtual IP address: 10.1.1.3/24
SwitchA
SwitchB
SwitchC
SwitchD
UMG
VLAN
Ethernet0/0/2
Backbone
Network
Ethernet0/0/1
Ethernet0/0/1
Ethernet0/0/2
Device
Interface
VLANIF interface
IP address
Switch A
Eth 0/0/1
VLANIF100
10.1.1.1/24
Eth 0/0/2
VLANIF200
192.168.0.1/24
Switch B
Eth 0/0/1
VLANIF100
10.1.1.2/24
Eth 0/0/2
VLANIF200
192.168.0.2/24
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
7 VRRP and VRRP6 Configuration