l
Configuring VLAN, For the configuration procedure, see VLAN Configuration
l
4.8 Configuring Basic Ethernet CFM
Data Preparation
To configure the one-way delay measurement in the VLAN, you need the following data:
No.
Data
1
Names of the MD and MA
2
ID of the MEP, name of the interface on which the MEP resides, and type of the MEP
3
Name of the VLAN bound to the MA
4
(Optional) Alarm threshold of the one-way frame delay measurement
5.3.2 Binding an MA to a VLAN
Binding an MA to a VLAN is a prerequisite for configuring the one-way frame delay
measurement in the VLAN.
Context
Do as follows on the devices configured with MEPs:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
cfm version
{
draft7
|
standard
}
The 802.1ag version is set to IEEE Standard 802.1ag-2007.
NOTE
IEEE 802.1ag has two versions: IEEE 802.1ag Draft 7 and IEEE Standard 802.1ag-2007. Y.1731 can be
used only on the device complying with IEEE Standard 802.1ag-2007. Therefore, run the cfm version
command to set the 802.1ag version to IEEE Standard 802.1ag-2007 before configuring Y.1731.
CAUTION
After the version is changed, all CFM configurations are deleted; therefore, use the cfm version
command with caution.
Step 3
Run:
cfm md
md-name
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
5 ITU-T Recommendation Y.1731 Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
264