vlan batch 2
#
cfm version standard
cfm enable
#
interface Ethernet0/0/1
port link-type trunk
port trunk allow-pass vlan 2
#
interface Ethernet0/0/3
port link-type trunk
port trunk allow-pass vlan 2
#
cfm md md1 level 6
ma ma1
map vlan 2
mep mep-id 1 interface ethernet 0/0/1 inward
mep ccm-send mep-id 1 enable
remote-mep mep-id 2
remote-mep ccm-receive mep-id 2 enable
#
return
4.18.5 Example for Configuring Association Between an EFM OAM
Module and an Interface
If association between an EFM OAM module and an interface is configured on a device, when
the EFM OAM module detects a fault, the EFM OAM module on the local device sends a fault
notification message to the OAM management module and triggers the physical status of the
interface bound to the EFM OAM module to go Down. When the physical status of the interface
becomes Down, the OAM management module sends a fault notification message to the EFM
OAM module. Then the EFM OAM module sends the fault notification message to the remote
device.
Networking Requirements
, EFM OAM is configured between Switch B and Switch C. When
Eth 0/0/2 on Switch B becomes Down, the EFM OAM module reports the fault to Eth 0/0/1 on
Switch C through the association mechanism. Then Eth 0/0/1 is triggered to go Down.
Figure 4-16
Networking diagram for configuring association between an EFM OAM module
and an interface
SwitchA
SwitchB
SwitchC
Ethernet/0/0/1
EFM OAM
Interface associated with
EFM OAM
Ethernet/0/0/1
Ethernet/0/0/2
Ethernet/0/0/2
Configuration Roadmap
The configuration roadmap is as follows:
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
4 Ethernet OAM Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
233