background image

3. Installing AP's Antenna Supports 

Quick Reference Guide for 
RTN510 AP Deployment  

Product version: 02 (2018-07-30) 

1. Preparing for Site Deployment 

2. Checking the Installation Environment 

4. Pre-installing RF Cables on the AP Side and Making Outdoor 
Network Cables 

Pole requirements: 

1. Check  the  positions  of  screws  on 

the supports. 

If the diameter of the pole is less than 78 mm, 
the screws are routed from the front clamp plate 
to the rear clamp plate through the inner hole.  

Upper support 

Lower support 

M6 x 16 square-neck bolt  

M8 x 20 hexagon bolt 

Upper support 

Lower support 

2. Install the upper and lower supports. 

Power supply requirements: 

The power for PoE power supply devices such as the PI or PC500 is available. 

The PI or PC500 has been installed at the site or together with the AP. 

1. To  facilitate  installation,  remove  the  PG  connector  and  protective  cover  from  the  P&E 

and COMBO(e) ports before installation.  

2. When securing the RF port of the AP, expose a thread of about 3 mm (2 to 3 circles).  

3. Apply waterproofing and anti-corrosion treatments on the two RF ports.  

Expose 2 to 3 
circles of 
threads on the 
connector.  

Wrap one 

layer of 

insulation tape. 

Wrap three layers 

of waterproof tape. 

Wrap three 

layers of 

insulation tape. 

Wrap it with 

binding straps on 

both ends. 

The height from 
the top of the 
connector to the 
lower part of the 
connector is  
30 mm. 

Vertical pole 

Diameter range: 48 to 114 mm 

1: white and 
orange 
2: orange 
3: white and green 
4: blue 
5: white and blue 
6: green 
7: white and brown 
8: brown 

1. The outdoor network cable connector on the AP 

side does not need to be equipped with a 
protective cover.  

2. During crimping, the metal shield layer of the 

outdoor network cable and the metal shell of the 
RJ45 connector must be in good contact.  

3. After the outdoor network cable is prepared, check 

the wire sequence and use a multimeter or a 
network cable tester to test the connectivity. 

NOTICE 

NOTICE 

Tools and Documents 

Components and Cables 

Auxiliary Materials 

Adjustable wrench 

Crimping tool, diagonal 
pliers 

M3 and M6 hex key 

Smartphone on which the 
MDT APP is installed, 
compass 

Planning document 

Hose clamp 

Binding strap 

Waterproof tape 

ESD tape 

Network cable 
grounding clip x 2 

Scan the QR code for MDT APP 

installation. The phone system version is 

Android 4.0 or later, and the camera 

resolution is greater than 8 megapixels.  

MDT can be used for deployment only after being registered 

and approved by Huawei.  

The registration information must be consistent with the 

information reported to Huawei for approval.  

The value is 
specified by 
Huawei 
engineers based 
on the project. 

AP 

AP antenna 

AP grounding clip 

Outdoor shielded  
network cable (made on site) 

Optical module and outdoor optical fiber 
(optional) 

AP mounting bracket 

AP antenna 
installation support 

RF cable x 2 

Содержание RTN510

Страница 1: ...e top of the connector to the lower part of the connector is 30 mm Vertical pole Diameter range 48 to 114 mm 1 white and orange 2 orange 3 white and green 4 blue 5 white and blue 6 green 7 white and brown 8 brown 1 The outdoor network cable connector on the AP side does not need to be equipped with a protective cover 2 During crimping the metal shield layer of the outdoor network cable and the met...

Страница 2: ...Outdoor network cable Outdoor optical fiber optional P E port Outdoor network cable optional COMBO e port RF port H RF port V GE o port RF port V RF port H 8 Installing Cables a Tools and Documents Components and Cables Auxiliary Materials AP with two RF cables AP antenna with antenna support AP grounding clip Outdoor shielded network cable Optical module and outdoor optical fiber optional Adjusta...

Страница 3: ...m the tower body to the outdoor cable tray and ground it 1 m away from the outdoor cable tray 2 Ground the outdoor network cable 0 5 m to 1 m away from the equipment room or outdoor cabinet except in the following cases The AP is connected to equipment that can be installed outdoors such as PC500 or outdoor PI the distance between the tower and the outdoor cabinet equipment room is less than 5 m 3...

Страница 4: ...he DCN If APs are not deployed on the same site set this status to Enabled On The Server When APs are deployed on the same site only one AP is configured as Enabled On The Server and other APs are configured as Enabled On The Client When the DHCP server is enabled set this parameter based on the IP address of the sub interface created on the router for the DCN if the upper layer network is a Layer...

Отзывы: