Label
Information
Sample Label
Parameter
Meaning of the Parameter
(3): T/R spacing
Indicates the T/R spacing (MHz) of the
ODU.
Some ODUs support two T/R
spacings, refer to
(4): Sub-band
Indicates the sub-band of the ODU,
which is expressed in letter.
(5): Tx high/low
station
P: Tx high station
N: Tx low station
(6): Level of the
output power
S: standard power
H: high power
ODU code
(ITEM)
52410002
-
Indicates the code of the ODU.
Description of
the ODU
(DEPICT)
7275~7338MHz,161MHz,Hi
②
①
③
(1): Transmit
frequency range
Indicates the transmit frequency range
(MHz) of the ODU.
(2): T/R spacing
Indicates the T/R spacing (MHz) of the
ODU.
Some ODUs support two T/R
spacings, refer to
(3): Tx high/low
station
Hi: Tx high station
Lo: Tx low station
Serial number
of the ODU
(S/N)
21524100021603000101
-
Identifies the ODU uniquely.
Bar code area
bar code area
-
Indicates the bar code of the serial
number of the ODU.
1.7 Technical Specifications
This technical specifications of the ODU include modulation mode, frequency band, transceiver
performance, IF performance, mechanical behavior and power consumption, and frequency
information.
NOTE
Huawei is always committing itself to providing consummate ODUs to clients, and thus the categories and
technical specifications of the ODUs may be updated irregularly. This document provides only the ODU
information that is available before the release of this document. For the latest documents, contact Huawei
engineers.
1 ODU
OptiX RTN 600 ODU
Hardware Description
1-8
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 06 (2010-05-30)