2.
Biological Environment
(1) Avoid multiplication of microbe, such as eumycete and mycete.
(2) Avoid rodentia animals such as mice.
3.
Air Cleanliness
(1) No explosive, electric-conductive, magnetic-conductive or corrosive dust.
(2) The density of the mechanical active substances complies with the requirements
listed in Table 10-28.
Table 10-28
Density for mechanical active substances
Mechanical active substance
Content
Dust particle
≤
3x10
5
particles/m³
Suspending dust
≤
0.4 mg/m³
Precipitable dust
≤
15 mg/m²·h
Gravel
≤
100 mg/m³
(3) The density of the chemical active substances complies with the requirements
listed in Table 10-29.
Table 10-29
Density for chemical active substances
Chemical active substance
Content
SO
2
≤
0.20 mg/m³
H
2
S
≤
0.006 mg/m³
NH
3
≤
0.05 mg/m³
Cl
2
≤
0.01 mg/m³
HCl
≤
0.10 mg/m³
HF
≤
0.01 mg/m³
O
3
≤
0.005 mg/m³
CO
≤
5.0 mg/m³