Prerequisite
l
The NE must be created successfully.
l
You must be an NM user with "NE operator" authority or higher.
Procedure
Step 1
Double-click the unconfigured NE on the Main Topology. Then, the
NE Configuration
Wizard
dialog box is displayed.
Step 2
Select
Upload
and click
Next
. Then, the
Confirm
dialog box is displayed.
Step 3
Click
OK
to start the upload. When the uploading is completed, the
Operation Result
dialog
box is displayed, indicating that the operation succeeded.
Step 4
Click
Close
.
----End
2.3 Checking Board Parameters
To learn about board parameter status, you can check board parameters. Before configuring the
boards in actual networking, you need to check board parameters and ensure that the board
parameters meet the requirements of actual networking.
Procedure
Step 1
Select the corresponding navigation path and check the related board parameters.
1.
Check the SDH board parameters. For the SDH board parameters, see
Table 2-1
SDH board parameters
Boar
d
Type
Paramet
er
Navigation
Path
Application Scenario
SDH
Laser
Switch
a. In the NE
Explorer,
select a board.
b. Choose
Configuratio
n
>
SDH
Interface
from
the
Function
Tree.
c. Click
By
Board/Port
(channel)
and
select
Port
from the
When configuring MSP shared services on an
optical interface of a board, enable this
parameter.
When configuring services on an optical
interface of a board, enable this parameter.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
2 Creating the Network
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-9