5.5.2 Changing the Values of Protection Subnet Parameters
5.5.1 Deleting Protection Subnets
Before you delete an NE or a fiber/cable connection on the U2000, you need to delete the related
protection subnets.
Prerequisite
l
You must be an NM user with "network maintainer" authority or higher.
l
If trails are configured on the protection subnet that you need to delete, delete the trails
first.
Procedure
Step 1
Choose
Service
>
SDH Protection Subnet
>
Manage SDH Protection Subnet
from the Main
Menu.
Step 2
Right-click the protection subnet to be deleted and choose
Delete from the NM
,
Delete from
the NE
, or
Delete All from the NM
from the short-cut menu.
NOTE
The methods of deleting a protection subnet are as follows:
l
Delete from the NM
: If
Delete from the NM
is selected, the relations between the protection subnet and
each logical system on the NE side are deleted so that the fibers can be deleted and reloading can be
performed. This command is not delivered to the NE and does not affect the services. The deleted protection
subnet can be located by using the search feature. The U2000 locates it according to the NE layer protection
information.
l
Delete from the NE
: If
Delete from the NE
is selected, the protection subnet, logical systems on the NE
side, and all the services on the protection subnet are deleted. The deleted protection subnet cannot be restored
and needs to be created again.
l
Delete All from the NM
: If
Delete All from the NM
is selected, the data of the protection subnet except
the fibers at the network layer is deleted. The deleted protection subnet can be located by using the search
feature. It is recommended that you do not select this option, because a large amount of data is deleted.
Step 3
Click
Yes
in the
Operation Prompt
dialog box indicating that the operation succeeded. Then,
the
Operation Result
dialog box is displayed.
NOTE
If
Delete from the NE
is selected, you need to confirm the operation again.
Step 4
Click
Close
.
----End
5.5.2 Changing the Values of Protection Subnet Parameters
In the case of the SDH equipment, you can set the parameters of the MSP protection subnet by
using the protection subnet maintenance function.
5 Modifying the Configuration Data
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
5-14
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)