Figure 5-16
Affixing a label to a signal cable
Affixing side
2~3 mm
1
06
A 01 2
A
TO:
Affixing a Label to a Power Cable
Remove a label from the bottom of the label page, and then attach it to the concave part on either
side of the identification plate of a cable tie. Ensure that the label directions are consistent in the
equipment room. The cable tie should be fastened 2 cm (0.788 inch) away from the connectors.
In special cases, the labels can be affixed to other positions.
Cable ties should be fastened at both ends of a cable. After bundling the cables, the completed
identification plate should be visible on the top of the cable in the horizontal cabling, or on the
right side of the cable in the vertical cabling. Make sure that the label points outwards, as shown
in
.
Figure 5-17
Appearance of a label affixed to a power cable
5.15 Setting Up a Heartbeat Network for CNENs
This section explains how to set up a heartbeat network for CNENs. The heartbeat network
provides a platform for CNENs (2 or 4) to perceive and communicate with.
Prerequisites
The following tools and materials have been ready:
OceanStor N8500 Clustered NAS Storage System
Installation Guide (for T Series V100R005)
5 N8500 Installation (with the S2600T Storage System as the
Storage Unit)
Issue 02 (2015-09-22)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
60