Item
Description
Naked Crimping Terminal,OT,10mm^2,M8,Tin Plating,Naked Ring
Terminal
Cable
Power Cable,-450/750V,H07Z-K UL3386,10mm^2,Blue,Low Smoke Zero
Halogen Cable
Power Cable,-450/750V,H07Z-K UL3386,10mm^2,Black,Low Smoke
Zero Halogen Cable
4.2 Chassis and Cabinet Grounding Cable
This section describes the structure and technical specifications of the chassis and cabinet ground
cable.
4.2.1 Introduction
The chassis and cabinet ground cables are used to ground a chassis and a cabinet. Before the
delivery of a device, ground cables are correctly connected to the front, back and side doors of
the cabinet.
4.2.2 Structure
The connector of the chassi and cabinet ground cable is the same as the connector of the DC-
input power cable.
4.2.3 Technical Specifications
lists the technical specifications of the NE40E-X1 and cabinet ground cable..
Table 4-3
Technical specifications of the NE40E-X1 and cabinet ground cable
Item
Description
PGND cable
Terminal
Naked Crimping Terminal,OT,6mm^2,M4,Tin
Plating,Naked Ring Terminal
Cable type
Power Cable,-450/750V,H07Z-K UL3386,6mm^2,oli-
vine
Fireproof class
CM
lists the technical specifications of the NE40E-X2 and cabinet ground cable..
HUAWEI NE40E-X1 & NE40E-X2 Universal Service
Router
Hardware Description
4 Cables
Issue 02 (2011-09-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
75