5 Power
Issue ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
37
Component
Status
under-voltage or over-voltage.
When the indicator is off, the power supply
modules are powered off or the hardware of
the power supply modules is faulty.
IN
When the indicator is steady green, the
power input is normal.
When the indicator is off, there is no -48 V
or -60 V power input.
The DC power monitoring channel can implement real-time monitoring on power supply.
In addition, the DC power monitoring channel allows you to query the manufacturing ID,
input voltage, and temperature of the power supply modules in real time, and supports
real-time reporting of power supply alarms.
You do not need to connect protection ground cables to the power supply modules, but
the protection ground cable for the chassis must be properly grounded. DC power cables
include a -48 V power cable and an RTN ground cable. The required cable length
depends on the distance between the cabinet and the power distribution cabinet for the
device. The DC power cables need to be prepared according to the required lengths on
site.
Technical Specifications
Item
Specification
Dimensions (H x D x W)
19.8mm x 211.8mm x 96.5mm (0.77 in. x 8.33 in. x 3.79
in.)
Weight
0.4 kg (0.88 lb)
Rated DC input voltage
-48V/-60V DC
DC input voltage range
-40V to -72V DC
Maximum current
10.5 A
Circuit breaker of each channel
32 A
Typical power consumption
13 W
5.2.4 AC Power System
Overview
Table 5-10
Power attributes
Attribute
Description
Description
AC power