Connecting the External Clock/Time Cables
CLK
TOD
a. Making the external clock and time cables according to the pin definition table
b. Connecting the External Clock/Time Cables
The interfaces CLK/TOD, CLK0/TOD0, and CLK1/TOD1 on the NE MPU use the same clock source and
clock cable. The NE08E-S6 with a CXPB board is used as an example here.
6
Connecting the Network Management Cable
NM
ETH/OAM
•The NMS cable is a serial cable and has
different pin arrangement than a common
network cable.
•For details about connecting a serial cable, see
the "Making a Serial Cable" in the
Installation
Guide
.
NOTE
NOTE
Color
PIN
Pin of the CLK and TOD Interfaces
120-hm external clock
External time (1PPS + time
information)
External time (DCLS)
White/orange
1
Rx negative of external clock
Not defined
Not defined
Orange
2
Rx positive of external clock
White/green
3
Not defined
RS422 input/output negative of
1PPS signals
RS422 input/output negative of DCLS
time signals
Green
4
Tx negative of external clock
Grounding
Grounding
Blue
5
Tx positive of external clock
White/blue
6
Not defined
RS422 input/output positive of 1PPS
signals
RS422 input/output positive of DCLS
time signals
White/brown
7
RS422 input/output negative of
time information
Not defined
Brown
8
RS422 input/output positive of time
information