
Technical Specifications
7
Login to the WebUI in IDU+ODU Mode
5
The web-based user interface (WebUI) of the N5368X provides a browser-based interface to
configure and manage the device with ease. This section uses the IDU+ODU architecture as an
example.
When a PC is used for direct login to the CPE, manually configure the IP address of the PC to be
in the same network segment as the IP address of the IDU.
1. On the task bar of the Windows operating system, choose
Start > Run
. Type
cmd
in the
displayed dialog box and press
Enter
. The command line interface is displayed.
2. Enter
route add 192.168.8.0/24 192.168.3.1 -p
.
· If the N5368X has accessed the network, you can configure the IDU to automatically obtain an IP
address to maintain the N5368X.
· If the N5368X has not accessed the network, you need to manually enter the IP address on the
IDU to configure and maintain the N5368X.
NOTE
·
192.168.3.1 is used as an example of the default IP address of the IDU. The default IP address of
the 5G CPE is 192.168.8.1, and the subnet mask is 255.255.255.0.
·
If the CPE is accessed through the IDU, obtain the PC address by referring to the corresponding
device guide.
·
If the CPE is accessed through the IDU, an appropriate address must be configured on the WAN
side of the IDU. If the WAN side does not obtain a valid IP address, manually add on the IDU an IP
address that is in the same network segment as the 5G CPE N5368X.
·
It is strongly recommended that the IDU be configured to obtain the WAN IP address dynamically
by DHCP. Otherwise, when only the N5368X is restarted to access the network, the IDU WAN IP
address may not match the IP address allocated by the network side, causing service exceptions.
NOTE
·
If you use Internet Explorer, Internet Explorer 11.0 or later is preferred.
·
On Internet Explorer browsers earlier than version 11.0, choose Internet
Options > Advanced >
Settings > Security
to enable TLS 1.2.
NOTE
·
The system forcibly requests you to change the login password upon the first login. For security
purposes, it is strongly recommended that you periodically change the login password.
·
A maximum of three incorrect login attempts are allowed during login or password modification.
After three consecutive login failures, the login page will be locked for 3 minutes.
·
If you do not perform any operation within 5 minutes after a successful login to the WebUI, you will
be forcibly logged out.
1
Login to the WebUI in Indoor Integrated Device Mode
6
The web-based user interface (WebUI) of the N5368X provides a browser-based interface to
configure and manage the device with ease. This section uses the indoor integrated device
architecture as an example.
When a PC is used for direct login to the CPE, ensure that the IP address of the PC is in the same
network segment as the IP address of the N5368X by means of manual configuration or DHCP.
1. On the task bar of the Windows operating system, choose
Start
>
Run
. Type
cmd
in the
displayed dialog box and press
Enter
. The command line interface is displayed.
2. Manually configure the IP address of the PC on the CLI.
NOTE
1
Determine whether the N5368X is connected to the network:
2
Start the Internet Explorer, enter
http://192.168.8.1
in the address box, and press
Enter
.
3
Enter the user name and password to log in to the WebUI. The default user name and password are
both
admin
.
4
NOTE
·
If you use Internet Explorer, Internet Explorer 11.0 or later is preferred.
·
On Internet Explorer browsers earlier than version 11.0, choose Internet
Options > Advanced >
Settings > Security
to enable TLS 1.2.
NOTE
·
The system forcibly requests you to change the login password upon the first login. For security
purposes, it is strongly recommended that you periodically change the login password.
·
A maximum of three incorrect login attempts are allowed during login or password modification.
After three consecutive login failures, the login page will be locked for 3 minutes.
·
If you do not perform any operation within 5 minutes after a successful login to the WebUI, you will
be forcibly logged out.
Start the Internet Explorer, enter
http://192.168.8.1
in the address box, and press
Enter
.
2
Enter the user name and password to log in to the WebUI. The default user name and password
are both
admin
.
3
For details about how to log in to the WebUI of an IDU, see the user manual of the IDU.
5
The default IP address of the 5G CPE is 192.168.8.1 and the subnet mask is 255.255.255.0.
5G NR: n78/n77/n41/n38
LTE FDD: Band 1/Band 3/Band 7/Band 8/Band 20/Band 28
LTE TDD: Band 38/Band 40/Band 41/Band 42/Band 43
WLAN: 2.4 GHz/5 GHz
5G NSA: 23 dBm@1T
5G SA: 26 dBm@2T
LTE: 23 dBm
ODU WLAN 5G: 14 dBm
ODU WLAN 2.4G: 16 dBm
N5368X Technical
Specifications
Power adapter
Technical
Specifications
Operating
Frequency Bands
Maximum
Transmit Power
Vendor Model
Output Voltage
Output Power
HW-190126D0D
19 V ± 5%
24 W
The supported operating frequency bands vary with areas.
The n78 frequency band range is 3400–3800 MHz.
NOTE
The supported WLAN maximum conducted transmit power
varies with areas.
NOTE