32
HUAWEI MG301 B2B Module
HardwareGuide
Antenna Interface
4.4
ESD Protection for the Antenna Interface
In practical application, pay attention to the ESD protection for the antenna interface
of the MG301 B2B module. Incorrect operation may result in permanent damage to
the RF components.
Figure 4-4 shows the ESD protection circuit recommended for the antenna interface.
Figure 4-4
ESD protection circuit recommended for the antenna interface
HUAWEI Module
(Modem)
RF switch
It is recommended that you pay attention to the junction capacitance of the TVS
diode when you choose the model of the TVS diode. Ensure that the junction
capacitance of the TVS diode is lower than 1 pF.
4.5
RF Specifications of the Antenna Interface
Table 4-2 lists the RF specifications of the antenna interface in the MG301 B2B module.
Table 4-2
RF specifications of the antenna interface in the MG301 B2B module
Specification
Minimum
Value
Typical
Value
Maximum
Value
Unit
Uplink frequency range
(Mobile station to base transceiver
station)
GSM 850
824
849
MHz
E-GSM 900
880
915
MHz
GSM 1800
1710
1785
MHz
Huawei Proprietary and Confidential Copyright ©
Huawei Technologies Co., Ltd