Table 5-2
Operating and storage temperatures
Specification
Min.
Max.
Unit
Normal operating temperature
–10
+55
°C
Extended operating temperature
[1]
–20
+70
°C
Ambient storage temperature
–40
+85
°C
[1]: When the ME906s module works at
–20°C to –10°C or +55°C to +70°C,
NOT
all its RF
specifications comply with the 3GPP specifications.
5.4 Power Supply Features
5.4.1
Input Power Supply
Table 5-3 lists the requirements for input power of the ME906s module.
Table 5-3
Requirements for input power
Parameter
Min.
Typ.
Max.
Ripple
Unit
3.3V
3.135
3.3
4.4
0.05
V
Figure 5-1
Power supply during burst emission
The minimum value of the power supply must be guaranteed during the burst (with 2.5 [email protected]
V peak in GSM, GPRS or EGPRS mode).
Table 5-4
Requirements for input current
Power
Peak (GSM 1 slot)
Normal (WCDMA)
Normal (LTE 23 dBm)
3.3 V
2.5 A
1.1 A