2
Figure 2
Wall-mount Installation
Put HWSP-3SA on the position, align the mounting holes of the splitter with two
anchor holes, and fix the splitter on the wall with two screws.
Step 2
Hang on wall.
Drill two holes and drive the fish-like anchor the same like
Step 1
but the
distance between two holes must be 27mm. Drive the screws in the anchors as
the support screws.
Make the screw caps 12mm protruded from the wall-surface.
Hang the splitter on the support screws with the hanging hole on back cover of
the splitter.
3 Connection
RJ-11 jack and 6-hole terminal block are connected in parallel and allow either to be
used for installation.
Step 1
Locate Tip (Green) and Ring (Red) from the network interface device (NID)
and disconnect from premises wiring.
Step 2
Connect network side Tip and Ring leads to RJ-11 Connector or terminal on
splitter marked LINE.
Step 3
Connect premise wire to RJ-11 connector or terminal on the splitter marked
PHONE.
Step 4
Connect VDSL equipment to either RJ-11 marked MODEM or the push-pin
terminal.
This Unit is intended for telephone circuit at 150 mA or less and a maximum of 56.6
VDC, ringing voltage not exceed 15V rms.
To reduce the risk of fire use only No.26 AWG or Larger telecommunication
line record.
If the terminal block is used for the installation, then the installation should
be performed by qualified service personnel.