
8.4.10 Installing an M.2 FRU on the Avago SAS3004iMR PCIe
RAID Controller Card
The M.2 FRU on the Avago SAS3004iMR RAID controller card is hot swappable.
Procedure
Step 1 Determine the positions and slots of the M.2 FRUs on the Avago SAS3004iMR
RAID controller card.
Figure 8-26 Positions and slots of the M.2 FRUs
Step 2 Remove the M.2 FRU filler module.
NO TE
Perform this step only when you configure an M.2 FRU filler module.
Step 3 Install an M.2 FRU on the Avago SAS3004iMR PCIe RAID controller card.
1. Take a spare M.2 FRU out of its ESD bag.
2. Open the handle of the M.2 FRU and push the M.2 FRU into the slot of the
Avago SAS3004iMR RAID control card. See (1) in
.
3. Close the handle of the M.2 FRU. See (2) in
.
FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide
8 Parts Replacement
Issue 17 (2021-03-09)
Copyright © Huawei Technologies Co., Ltd.
64