l
If yes, go to
.
l
Step 13
Install the PCIe card.
Step 14
Install the cover.
Step 15
Install the compute node.
.
Step 16
Power on the compute node.
Step 17
Configure the RAID controller card.
The following uses the LSI SAS3008IR RAID controller card as an example.
1.
Log in to the Configuration Utility.
For details, see
LSI SAS3008IR
>
Initial Configuration (Legacy/Dual Mode)
or
Initial
Configuration (EFI/UEFI Mode)
>
Logging In to the Configuration Utility
in
Huawei V5 Server RAID Controller Card User Guide
2.
Activate RAID.
For details, see
LSI SAS3008IR
>
Common Tasks (Legacy/Dual Mode)
>
Activating a
RAID Configuration
Huawei V5 Server RAID Controller Card User Guide
----End
4.3.5 Removing the Avago SAS3004iMR PCIe RAID Control Card
Procedure
Step 1
Power off the compute node.
Step 2
Remove the compute node.
Step 3
Place the compute node on the ESD workstation.
Step 4
Remove the cover.
.
Step 5
Remove the air duct.
.
Step 6
Determine the position of the Avago SAS3004iMR RAID controller card.
Step 7
Remove the M.2 FRU from the Avago SAS3004iMR RAID controller card.
FusionServer Pro CH121 V5 Compute Node
Maintenance and Service Guide
4 Parts Replacement
Issue 06 (2019-08-10)
Copyright © Huawei Technologies Co., Ltd.
60